Test Summary
2.1
Test Procedure
Test Summary
This section shows the test setups used and the tests performed in evaluating the EVM.
Setup: The bq2406xEVM board requires a 5-VDC, 1-A power source to provide input power and a
single-cell Li-ion or Li-polymer battery pack. The test setup connections and jumper setting selections are
configured for a stand-alone evaluation but can be changed to interface with external hardware such as a
microcontroller.
Table 2. I/O and Jumper Connections
Jack
Connect To:
J1-DC+
Power supply positive, preset to 5 VDC, 1-A current limit.
J1-DC–
Power supply ground
J2-BAT+
Positive battery pack terminal
J2-BAT–
Negative battery pack terminal
J2-TS
NC
J2-BAT–
NC
J3-STAT1
External hardware if J4-EXT is jumpered (Not jumpered from factory)
J3-STAT2
External hardware if J5-EXT is jumpered (Not jumpered from factory)
J3-DC–
Return for J3 signals
J3-PG
External hardware if J6-EXT if jumpered (Not jumpered from factory)
J4 (Jumper)
STAT1 indication location –LED
(1)
(EVM) | EXT
J5 (Jumper)
STAT2 indication location –LED
(1)
(EVM) | EXT
J6 (Jumper)
PG indication location –LED
(1)
(EVM) | EXT
J7 (Jumper)
TMR enable - Installed
(1)
(1)
Factory jumper selections are shown in BOLD.
Set up the evaluation board as previously described by making the necessary I/O connections and jumper
selections. Prior to test and evaluation, it is important to verify that the maximum power dissipation on the
IC is not exceeded, P
(MAX)
= 1.5 W.
1. Turn on the power supply, which was preset to 5 VDC, and 1 A for the current-limit setting.
2. The bq2406x enters preconditioning mode if the battery is below the V(LOWV) threshold. In this mode,
the bq2406x precharges the battery with a low current (typically IO(CHG) /10 = 0.7A/10 = 70 mA) until
the battery voltage reaches the V
(LOWV)
threshold or until the precharge timer expires. If the timer
expires, then the charge current is terminated and the bq2406x enters fault mode. Both LEDs turn off
when in fault mode. Toggling input power or battery replacement resets fault mode.
3. Once the battery voltage is above the V
(LOWV)
threshold, the battery enters fast-charge mode. This
EVM is programmed for 0.7 A of fast-charging current.
4. Once the battery reaches voltage regulation (4.2 V), the current tapers down as the battery reaches its
full capacity.
5. The battery remains at the fast charge mode until either the charge timer expires or the charge
termination current threshold is reached.
6. Once the charge terminates, J7 (TMR jumper) can be removed, putting the IC in LDO mode, and the
charger should turn on the supply 4.2 V or the programmed fast-charge current. Replacing the jumper
allows the IC to terminate properly. Note that loads across the battery can affect termination.
7. If the battery discharges to the recharge threshold, the charger starts fast charging.
2
bq2406x Evaluation Module
SLUU235 – February 2006