SNVS824C – JUNE 2012 – REVISED MARCH 2013
Table 45. Current, Power and Warning Conversion Coefficients (R
S
in m
Ω
)
Commands
Condition
Format
Number of
m
b
R
Unit
Data Bytes
*READ_IIN, READ_AVG_IIN
CL = GND
DIRECT
2
13661 x R
S
-5200
-2
A
MFR_IIN_OC_WARN_LIMIT
*READ_IIN, READ_AVG_IIN
CL = VDD
DIRECT
2
6854 x R
S
-3100
-2
A
MFR_IIN_OC_WARN_LIMIT
*READ_PIN, READ_AVG_PIN,
CL = GND
DIRECT
2
736 x R
S
-3300
-2
W
READ_PIN_PEAK
MFR_PIN_OP_WARN_LIMIT
Care must be taken to adjust the exponent coefficient, R, such that the value of m remains within the range of -
32768 to +32767. For example, if a 5 m
Ω
sense resistor is used, the correct coefficients for the READ_IIN
command with CL = VDD would be m = 6830, b = -310, R = -1.
A Note on the "b" Coefficient
Since b coefficients represent offset, for simplification b is set to zero in the following discussions.
Determining Telemetry Coefficients Empirically with Linear Fit
The coefficients for telemetry measurements and warning thresholds presented in
are adequate for the
majority of applications. Current and power coefficients must be calculated per application as they are dependent
on the value of the sense resistor, R
S
, used.
provides the equations necessary for calculating the
current and power coefficients for the general case. The small signal nature of the current measurement make it
and the power measurement more susceptible to PCB parasitics than other telemetry channels. This may cause
slight variations in the optimum coefficients (m, b, R) for converting from Direct Format digital values to real-world
values (e.g. Amps and Watts). The optimum coefficients can be determined empirically for a specific application
and PCB layout using two or more measurements of the telemetry channel of interest. The current coefficients
can be determined using the following method:
1. While the LM25066I/A is in normal operation, measure the voltage across the sense resistor using kelvin test
points and a high accuracy DVM while controlling the load current. Record the integer value returned by the
READ_AVG_IIN command (with the SAMPLES_FOR_AVG set to a value greater than 0) for two or more
voltages across the sense resistor. For best results, the individual READ_AVG_IIN measurements should
span nearly the full scale range of the current (for example, voltage across R
S
of 5 mV and 20 mV).
2. Convert the measured voltages to currents by dividing them by the value of R
S
. For best accuracy, the value
of R
S
should be measured.
assumes a sense resistor value of 5 m
Ω
.
Table 46. Measurements for linear fit determination of current coefficients
Measured voltage across
Measured Current (A)
READ_AVG_IIN
R
S
(V)
(integer value)
0.005
1
648
0.01
2
1331
0.02
4
2698
3. Using the spreadsheet or math program of your choice, determine the slope and the y-intercept values
returned by the READ_AVG_IIN command versus the measured current. For the data shown in
:
READ_AVG_IIN value = slope x (Measured Current) + (y-intercept)
slope = 683.4
y-intercept = -35.5
4. To determine the ‘m’ coefficient, simply shift the decimal point of the calculated slope to arrive at an integer
with a suitable number of significant digits for accuracy (typically 4) while staying with the range of -32768 to
+32767. This shift in the decimal point equates to the ‘R’ coefficient. For the slope value shown above, the
decimal point would be shifted to the right once hence = -1.
5. Once the ‘R’ coefficient has been determined, the ‘b’ coefficient is found by multiplying the y-intercept by 10
-
R
. In this case the value of = -355.
Calculated Current Coefficients:
= 6834
Copyright © 2012–2013, Texas Instruments Incorporated
49