Texas Instruments TPS61050-215 Evaluation Kit TPS61050EVM-215 TPS61050EVM-215 TPS61050EVM-215 데이터 시트

제품 코드
TPS61050EVM-215
다운로드
페이지 45
www.ti.com
FLASH_SYNC or (SFT)
LED CONTROL
TIMER
STIM
I
FLASH
I
TORCH
RESET (SF)
FLASH_SYNC or (SFT)
LED CONTROL
TIMER
STIM
I
FLASH
I
TORCH
RESET (SFT)
FLASH_SYNC or (SFT)
LED CONTROL
TIMER
STIM
I
FLASH
I
TORCH
RESET (SFT)
MODE OF OPERATION: FLASH BLANKING (TPS61050)
I
FLASH
I
TORCH
LED Current
Free
Free
LED Turn-On
Command
I2C Bus
FLASH_SYNC
GPIO (Tx-MASK)
Free
LED Turn-Off
Command
SLUS525 – MARCH 2007
DETAILED DESCRIPTION (continued)
The Flash strobe is edge sensitive (STT = 1): The LED strobe pulse is triggered by a rising edge
When FLASH_SYNC and START_FLASH/TIMER (SFT) are both low, the LED operation is set to the torch
current level without timeout.
The duration of the flash pulse is defined in the STIM register. The flash strobe is started by:
a rising edge of FLASH_SYNC signal.
a rising edge of START_FLASH/TIMER (SFT) bit.
Once running, the timer ignores any triggering signal, and only stops after a timeout (TO). The
START-FLASH/TIMER (SFT) bit is reset by the timeout (TO) signal.
Figure 35. Edge Sensitive Timer (Single Trigger Event)
Figure 36. Edge Sensitive Timer (Single Trigger Event)
Figure 37. Edge Sensitive Timer (Multiple Trigger
Events)
The TPS61050 device also integrates a general purpose I/O pin (GPIO) that can be configured either as a
standard logic input/output or as a flash masking input (Tx-MASK). This blanking function turns the LED from
flash to torch light, thereby reducing almost instantaneously the peak current loading from the battery. The
Tx-MASK function has no influence on the safety timer duration.
Figure 38. Synchronized Flash With Blanking Periods
20