Texas Instruments TPS65810 Evaluation Module TPS65810EVM TPS65810EVM 데이터 시트

제품 코드
TPS65810EVM
다운로드
페이지 99
www.ti.com
FUNCTIONALITY REFERENCE GUIDE – HOST INTERFACE AND SYSTEM SEQUENCING
INTERRUPT
CONTROLLER
INT
SDAT
SCLK
STATE MACHINE
AND RESET
CONTROLLER
HOT_RST
RESPWRON
TRSTPWON
SYS_IN
HOST INTERFACE
AND SEQUENCING
I2C ENGINE
OUT
0 .1 uF
A 1
2
K
1
0
0
K
2
K
HOST
TPS 65810
1
0
0
K
A 1
A 1
R
5
R
3
R
2
R
4
C TRSTPWON
210 K
R 6
R 1
100 K
C 16
100 nF
1
0
0
K
V SM2
R
7
SLVS658B – MARCH 2006 – REVISED FEBRUARY 2007
INTERRUPT CONTROLLER, OPEN-DRAIN OUTPUT (INT)
System Parameters Monitored by Interrupt Controller
Power up
default
Supply Output
System
Charger Status
Input and Output
Power Good Fault
Status
ADC status
Transition
Power Transition
Detection
(1)
Modification
Charge: Pre
↔ Fast
SM1,
ADC conversion end
Thermal Fault or
↔Done
AC detected: yes
↔ no
SM2,
ADC
GPIO 1,2
DPPM:on
↔ off
USB detected: yes
↔ no
SM3,
Input out of range
configured as
Charge Suspend: on
Input OVP: yes
↔ no
All interrupt
LDO1, LDO2,
External resistive
external interrupt
off
System Power: AC
controller
LDO3, LDO4,
load connected to
request
Thermal Foldback: on
USB
inputs set to
LDO5
ANLG1
↔ off
non-masked
Can be masked Individually
Can be masked as a group via a single I
2
C mask
via I
2
C. Blanked during
Can be masked Individually via I
2
C
register bit
initial power up
(1)
For all supplies (except) for SM3 an output fault is detected if the output voltage is below 90% of the programmed regulation voltage. In
the SM3 converter an output fault indicates that the output OVP threshold was reached.
EVENTS TRIGGERING TPS65810 OPERATING MODE CHANGES
EVENT
POWER GOOD FAULT
THERMAL
HARDWARE
SOFTWARE
DETECTION
(1)
FAULT
RESET
RESET
How transition is
Integrated regulator output
Internal IC junction
Using HOT_RST control
I
2
C register control bit
triggered
voltage below target value:
temperature
pin
SM1, SM2, SM3, LDO1,
LDO2,LDO3, LDO4, LDO5
Operating mode
Sets Sleep mode or starts a
Sets Sleep mode when
Generates external host
Generates external host
change
new power-up cycle when
thermal fault is detected
reset pulse at pin
reset pulse at pin
power good fault is detected
RESPWON when
RESPWON when I
2
C
(see state machine diagram).
HOT_RST=LO.
control bit is set.
Power good fault detection
Input and Battery power
Pulse duration set by
Pulse duration set by
comparators are blanked during
cycling required to exit
external capacitor.
external capacitor.
initial power-up.
sleep
Controls
Can be masked Individually via
Fixed Internal Threshold
External Input
Set via I
2
C
I
2
C.
(1)
For all supplies (except) for SM3 an output fault is detected if the output voltage is below 90% of the programmed regulation voltage. In
the SM3 converter an output fault indicates that the output OVP threshold was reached.
Figure 26. Required External Components, Recommended Values, External Connections
32
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s):