Texas Instruments UCC28230 Intermediate Bus Converter 300-W Evaluation Module UCC28230EVM UCC28230EVM 데이터 시트

제품 코드
UCC28230EVM
다운로드
페이지 17
5.2
Equipment
5.3
Notes of Power Up and Power Down
Test Setup
www.ti.com
DC Input Source: The input source shall be a variable dc source capable of supplying between 40 V
DC
and 55 V
DC
with 10 A
DC
current rating.
Multimeters: Multimeters are used to measure the output voltage (DMM1), the input voltage (DMM3), the
output current (DMM2) and the input load current (DMM4).
Output Load: A programmable electronic load is recommended configurable for constant current mode
and capable of sinking 0 to 35 A
DC
from 8 V
DC
to 11 V
DC
. The output voltage can be monitored by
connecting a dc voltmeter, DMM1 to sense pins (TP23 and TP24) shown in
A dc current meter,
DMM2, may be inserted in series with the electronic load for accurate output current measurements.
Similarly, the input voltage can be monitored by connecting a dc voltage meter to sense pins (TP10 and
TP11). The input current can be monitored by a dc current meter too. These are shown in
.
Oscilloscope: Set the oscilloscope channel to ac coupling with 20-MHz bandwidth.
The following steps are guidelines for power up and power down of the EVM.
1. An ESD workstation is recommended. Make sure that an ionizer is on before the EVM is removed from
the protective packaging and power is applied to the EVM. Electrostatic smock and safety glasses
should also be worn.
2. Power Up
a. Prior to connecting the dc input source, limit the source current 6.5 A maximum. Make sure the dc
source is initially set between 43 V
DC
and 53 V
DC
prior to turning on. Connect the dc source to the
EVM as shown in
.
b. Connect the power meter as shown in
c. Connect the current meters DMM2 and DMM4 as shown in
.
d. Connect the volt meter DMM1 and DMM3 as shown in
.
e. For operation with a load, connect the electronic load to the EVM as shown in
Set the
LOAD to constant current mode with initial value of 0 A.
f.
Turn on the dc source and observe the output voltage. Since this is an output unregulated
converter, its output voltage is varying with both input voltage and load. Its output voltage varying
range is between 8.0 V
DC
and 10.8 V
DC
.
g. Vary the Load between 0 A and 30 A. The module is able to operating with higher current. For
operating with load current greater than 30 A, please consult the factory before doing so.
3. Power Down
a. Turn off the dc source.
b. Turn off the load.
6
Intermediate Bus Converter 300-W Evaluation Module
SLUU331 – July 2008