6.4.3
Command Line Interface Tab
Kit Operation
Clicking on Command Line Interface tab brings up a screen as shown in
, which provides a
flexible way to read and write to the TSC2004EVM by scripting.
Figure 5. Command Line Interface Tab
The line or lines of the script are typed or loaded into the Command Buffer. Then, clicking on the Execute
Command Buffer 
button runs the script.
The three LEDs on this tab and the req done LED light up (green) after the script execution is finished. If a
line of the script is a reading command, the read data is shown at the Read Data section; if the line of the
script is a writing command, the written data bytes also are returned to the Read Data section.
As
shows, three read buttons reveal the contents of the threshold, control, and status registers of
the TSC2004, displaying them in the Data Read/Written section of the screen. The data flow shows on the
top and is interpreted and listed correspondingly on the button