Texas Instruments Evaluation Module for TLV70433 TLV70433DBVEVM-712 TLV70433DBVEVM-712 데이터 시트

제품 코드
TLV70433DBVEVM-712
다운로드
페이지 11
I
IN
V
OUT
1 V/div
2 V/div
V
IN
C
1
C
2
C
4
www.ti.com
LDO Ground Current Measurement
4
LDO Ground Current Measurement
The LDO ground, or quiescent current (isolated from the load current), can be measured after taking these
steps:
Step 1.
Turn off the input power supply.
Step 2.
Remove the 0-
Ω
resistor R1 on the TPS70433PKEVM-712 EVM (or R2 on the
TPS70433DBVEVM-712 EVM).
Step 3.
Connect a current meter across pin 1 of J3 and pin 2 of J3.
Step 4.
Turn on the power supply, as disussed in
5
Test Results
This section provides typical performance waveforms for the TLV70433DBEVM-712 and the
TLV70433PKEVM-712.
5.1
Turn-On Sequence
shows the turn-on characteristic of the LDO. V
IN
(C
1
, yellow) quickly transitions to 5.0 V to turn on
the LDO. The output voltage, V
OUT
(C
2
, red), then ramps up to its nominal 3.3-V output in accord with the
control loop design after the input current surge I
IN
(C
4
, green) has sufficiently charged the input and
output capacitors.
Note:
C
1
, V
IN
: turn-on to 5 V;
C
2
, V
OUT
: 3.3-V turn-on ramp;
C
3
, Input rush current at turn-on
Figure 1. Turn-On Sequence
3
SBVU017 – January 2011
TLV70433DBVEVM-712, TLV70433PKEVM-712 Evaluation Modules
© 2011, Texas Instruments Incorporated