Texas Instruments TPS2556DRBEVM-423: Evaluation Module for TPS2556 TPS2556DRBEVM-423 TPS2556DRBEVM-423 데이터 시트

제품 코드
TPS2556DRBEVM-423
다운로드
페이지 10
www.ti.com
Getting Started
4
Getting Started
Preset the power supply to 5 V and turn off. Connect the power supply output to the input terminals of the
HPA423.
Slide S1 to disable the TPS2556 or TPS2557. Turn on the power supply to apply 5.0 V to the EVM
input-power terminals. VOUT should be 0 V.
Slide S1 to enable the device. For TPS2556, set S1 to LO; for TPS2557, set S1 to HI. VOUT should be
VIN + / - 0.3 V.
Set the oscilloscope to auto trigger mode and the horizontal-sweep to 4 ms/div. Set all vertical channels
for 2 V/div except the current probe set for 200 mA/div
4.1
Monitor
1. Input voltage at TP1
2. Output voltage at TP5
3. EVM input current
4. FAULT# status voltage at test point TP3
4.2
Verify EVM Output
1. Set the scope for normal trigger, single sweep. Trigger on VOUT, negative slope at about a 3.5-V level.
2. Momentarily short the output connector. A sample scope trace is shown in . Observe VOUT drops to 0
V
3. Input current rises to an amplitude of 400 mA + / - 50 mA, within 0 to 4 ms after VOUT low.
4. FAULT signal is low 2 ms to 20 ms after VOUT low.
5
Performace Data and Characteristics Curves
Figure 2. 100-k
Ω
R
ILIM
Enabled Into a Short Circuit
5
SLUU393 – November 2009
Using the TPS2556EVM-423 and TPS2557EVM-423
Copyright © 2009, Texas Instruments Incorporated