Texas Instruments BQ2003 Evaluation Module for NiCd/NiMH, linear DV2003L1 DV2003L1 데이터 시트

제품 코드
DV2003L1
다운로드
페이지 5
External Current Source Control (P1): Enables/dis-
ables on-board linear regulator.
Temperature Disable: Connecting a 10K
Ω resistor be-
tween THERM and GND or BAT– disables temperature
control.
Setup Procedure
1.
Configure DVEN, TM1, TM2, and number-of-cells
(NOC) jumpers.
2.
Connect the provided thermistor or a 10K
Ω resistor
across THERM to GND.
Note: RT1 and RT2 match the thermistor provided
and must be changed if a different thermistor type
is used (see Appendix A in the application note,
“Using the bq2003 to Control Fast Charge”).
3a. If using off-board regulation, close jumper P1 and
attach the MOD connector to the external current
control.
3b. If using on-board regulation, open jumper P1.
4.
If using the discharge-before-charge option, connect
a current-limiting discharge load from BAT+ to
DSCHG.
5.
If using the INHIBIT function, connect a switch
across J2 (IN to +V) or connect INH to the control-
ling signal source (3–5V).
6.
Attach the battery pack to BAT+ and BAT–. For
temperature control, the thermistor must contact
the cells.
7.
Attach DC current source to DC+ (+) and GND (–)
connections in J1.
3
DV2003L1
Symbol
Description
Minimum
Typical
Maximum
Unit
Notes
I
XTRKL
External additional trickle current
-
-
1
A
P
D
LM317 power dissipation
-
-
6
W
P
D
= I
DC+
* (V
DC+
– V
BAT+
– 2V)
I
DC+
LM317 input current
-
1.25
-
A
Configured rate.
Maximum LM317 input current
(with R13 = 0.83
Ω, minimum value)
-
1.5
-
A
R13 changed for
maximum rate.
V
DC+
LM317 regulation enabled
4.25 + V
BAT+
or 10
-
9.5 + V
BAT+
or 35
V
Notes 1, 2
External current source
10
-
9.5 + V
BAT+
or 35
V
V
BAT+
BAT+ input voltage
-
-
30
V
V
THERM
THERM input voltage
0
-
5
V
V
MOD
MOD output voltage
0
-
5
V
In series with R25
V
IN
Inhibit input signal
0
-
5
V
I
DSCHG
Discharge load current
-
-
2
A
Note:
1.
The voltage drop across the LM317, diodes, and resistors in charge path—with the LM317 enabled—
is approximately 4.25V. Maximum voltage drop across LM317 is primarily limited by the on-board
heat sink and should be controlled to limit heat dissipation to 6W in free air. Additional cooling is
necessary if the heat dissipation exceeds 6W.
2.
The input voltage must be greater than NOC * 1.8V + V
LOSS
for detection of battery absent and for
charge initiation on battery replacement.
Recommended DC Operating Conditions
Jumper Setting
On-Board Regulator
[ 1 2 ]
Disabled
1 2
Enabled