6.4.2.2
Test Mode Configuration (CFR1)
6.4.2.3
MAVF Configuration (CFR2)
6.4.2.4
Threshold Configuration
Kit Operation
Precharge Time
Sense Time
These two parameters are the time allowed to precharge the touch panel capacitance and then sense
to see if the screen is touched. For more details on these parameters, see the TSC2006 data sheet.
Detection of Pen Touch in Wait
This option is valid when the ADC is put into the host-controlled mode. Enabling this option puts the
pen touch detection in the background and allows the TSC2006 to pull its PINTDAV pin high if no pen
touch is detected while waiting for the host to issue a command, so that the host can decide if a
reading touch data command should or should not be issued.
Longer Sample Mode
Enabling this option adds an extra 500 ns of sampling time to the normal sampling cycle. It is disabled
by default.
TSC2006 features a touch screen test function to check if the 4-wire touch panel had been properly
connected and if there is short-circuitry. To implement the connection test, the resistance range of the
touch screen should be entered into CFR1. Select Short Circuit Panel Test to perform the short-circuitry
test function.
To perform a touch screen test, the Converter Function Selection must be set up in CB1 as X-Axis
Connection Test, Y-Axis Connection Test, or Short-Circuit Test. The multiple selector under CFR1
provides the access.
The test result returns to the STATUS register.
Another TSC2006 feature is the Batch Delay Mode, as shown in the CFR1 section. Under the
TSC-controlled ADC mode, this feature adds delay between ADC samples and thus controls the
time/interval between samples. The batch delay ranges from 0 ms to 100 ms.
The preprocessing MAV filter (MAVF) inside TSC2006 reduces sampling noise. See the data sheet for
details of the MAVF.
The CFR2 section has five selection buttons that can be used to enable/disable the MAVF on touch data,
X, Y, and Z, or nontouch data, AUX and Temperature.
Clicking on the MAV Filter Control option box brings up a list of settings on M and W values. Select an
eligible option from the list (do not select the Reserved) and the corresponding digital shows up at the next
box. Clicking on the digital box writes the selected value to the CFR2 register.
Zone detection is one of the new features the TSC2006 offers. Zone detection function was designed to
monitor the zone/range of the nontouch inputs, including AUX and TEMP1/TEMP2.
The four control registers inside TSC2006, used to set up the top and bottom thresholds of AUX and
TEMP1/TEMP2, can be accessed through the four moving slides in the Threshold Selection section. The
zone detection modes can be controlled/selected through the two option boxes at the bottom of the CFR2
section.
TSC2006EVM and TSC2006EVM-PDK
12
SLAU200 – January 2007