6.4.3.2
Down Load Script
Kit Operation
Example 3: Do the same as Example 2, but writing to CB0 to set ADC bias power OFF between
converter.
w 00 60 A9 24
Example 4: Writing the four threshold registers to set up the max=0xFF0 and min=0x00F.
w 00 42 0F F0 4A 00 0F 52 0F F0 5A 00 0F
Example 5: Reading the STATUS register content.
r 00 38 01 00
Example 6: Reading back Y, Y, Z1, and Z2 data registers.
r 00 02 04 00 0A 00 00 12 00 00 1A 00 00
To down load an existing script into the Control Buffer, first go into the File menu, and select Open
Command File...
, which opens a file-select window and allows you to browse and find a script file. Then,
click on Open and the script is loaded into the command buffer. An example is shown in
Figure 7. Open Script File and Load to Command Buffer