6.4.1
Human Interface
6.4.1.1
Touch Screen Control Function
Kit Operation
Start TSC2006 EVM software, the Human Interface tab shows up by default. The three sections on this
tab are shown in
Figure 3. Human Interface Tab
The touch screen box in this tab is updated when a touch is detected on the touch screen. As the touch
screen is drawn on, the motion on the touch screen is translated into pixels on this box. The software
takes X, Y, Z1, and Z2 readings which are shown to the right of the touch screen box. As the touch
pressure is increased, the pixel size increases; a lighter touch results in thinner pixel sizes.
The Z-value displayed is not totally what is described in the TSC2006 data sheet, because in the data
sheet equations, it is assumed that the resistance of the touch screen being used is known. The value
used in this program is calculated by Equation 1 of the TSC2006 data sheet, but without multiplying it by
the R
x-plate
resistance. This value is shown as beneath the measured touch data, X, Y, Z1, and Z2; and
normally ranges from 0 to 4, with larger numbers representing a more forceful press on the screen. Using
the Maximum Z Value to Display knob, you can set a threshold so that the program does not display
lightly pressed points. This threshold setting helps to eliminate display of spurious points that may result
from touch screen mechanical bouncing.
The display in the touch screen box can be cleared by pressing the Clear Graph button on the screen.