2.2.2
Load 1
2.2.3
Load 2
2.2.4
Meters
2.2.5
Wire Gauge
2.3
Equipment Setup
Test Summary
www.ti.com
A 10-V (or above), 2-A (or above) electronic load that can operate at constant current mode.
A 10-V (or above), 2-A (or above) electronic load that can operate at constant voltage mode.
Four Fluke 75 multimeters (equivalent or better)
Or:
Three equivalent voltage meters and one equivalent current meter
The current meter must be capable of measuring 2-A+ current.
All wires connected to the EVM input power supply and output load must use at least AWG 22. The
maximum current is up to 1 A.
1. Set the PS 1 for 0 V
±
100 mVdc, 2
±
0.1 A current limit, and then disable the output.
2. Connect the output of PS 1 to J1 (DC+, DC–).
3. Connect a voltage meter across J1 (DC+, DC–).
4. Connect the output of the Load 1 in series with a current meter (multimeter) to J2 (CHGIN) and J3
(GND). Turn on the power of the Load 1. Set the load current to 1.5 A
±
50 mA but disable the output.
5. Connect output of the Load 2 in series with a current meter (multimeter) to J4 (BAT+, BAT–).
6. Connect a voltage meter across J4 (BAT+, BAT–).
7. Set the voltage of Load 2 to 3.6 V
±
0.1 V, and disable output of Load 2.
8. JP1: ON, JP2 (BATEN, GND): ON, JP3: OFF, JP4: ON, JP5: ON, JP6: ON, JP7: OFF.
After the preceding steps have been taken, the test setup for HPA398 (bq2435x DSG EVM) appears as is
shown in
.
4
bq2435x DSG EVM for Li-Ion Charger Front-End Protection IC
SLUU365 – June 2009