Texas Instruments TPS23751 Evaluation Module TPS23751EVM-104 TPS23751EVM-104 데이터 시트

제품 코드
TPS23751EVM-104
다운로드
페이지 47
D
VC1
C
VC
ARTN
R
VC
V
C
T1
Bias WInding
DISCHARGE
RECHARGE
Hiccup Freque
1
1
F
37Hz
T
T
4.9ms
22.3
ncy :
ms
=
=
=
+
+
DISCHARGE
DISCHARGE
RECHARGE
T
4.9ms
Duty Cycle : D
18.0%
T
T
4.9ms
22.3ms
=
=
=
+
+
(
)
(
)
VC1
VC2
CUVH
DISCHARGE
TOTAL
C
C
V
10 F
0.47 F
3.2 V
T
4.9 ms
I
6.9 mA
+
´
m +
m
´
=
=
=
(
)
(
)
VC1
VC2
CUVH
RECHARGE
VC _ ST
C
C
V
10 F
0.47 F 3.2 V
T
22.3ms
I
1.5mA
+
´
m +
m ´
=
=
=
(
)
VC1
VC2
CUV
ST
VC _ ST
C
C
V
10.47 F 8.9 V
T
62.1ms
I
1.5mA
+
´
m ´
=
=
=
SSD
TOTAL
VC1
VC2
CUVH
T
I
3.01ms 6.9mA
C
C
6.49μF
V
3.2 V
´
´
+
=
=
=
GATE
DRIVE
C
TOTAL
DRIVE
VC _ OP
P
61.2mW
I
5.1mA
V
12 V
I
I
I
5.1mA
1.8mA
6.9mA
=
=
=
=
+
=
+
=
GATE
12
P
12 V
250 kHz
17 nC
61.2mW
10
=
´
´
´
=
SLVSB97C – JULY 2012 – REVISED JANUARY 2014
Compute gate drive power if V
C
is 12 V and Q
GATE
is 17 nC
(7)
This equation illustrates why MOSFET Q
G
should be an important consideration in selecting the switching
MOSFETs.
2. Estimate the required bias current at some intermediate voltage during the C
VC
discharge. For the TPS23751
and TPS23752, 12 V provides a reasonable estimate. Add the operating bias current to the gate drive
current.
(8)
3. Compute the required C
VC
based on startup within the typical softstart delay of 3.01 ms.
(9)
4. Choose a 10
μF electrolytic and 0.47 μF ceramic capacitor each rated for 16 V (minimum). Compute the
initial time to start the converter when operating from PoE. Using a typical bootstrap current of 1.5 mA,
compute the time to startup.
(10)
5. Compute the fault duty cycle and hiccup frequency
(11)
(12)
(13)
(14)
Switching Transformer Considerations and R
VC
Care in design of the transformer and V
C
bias circuit is required to obtain hiccup overload protection. Leading-
edge voltage overshoot on the bias winding may cause V
C
to peak-charge, preventing the expected tracking with
output voltage. Some method of controlling overshoot is usually required. The method may be as simple as a
series resistor, or an R-C filter in front of D
VC1
. Good transformer bias-to-output-winding coupling results in
reduced overshoot and better voltage tracking.
Figure 31. V
C
Pin Interface
R
VC
as shown in
helps to reduce peak charging from the bias winding. Reduced peak charging
becomes especially important when tuning hiccup mode operation during output overload. Typical values for R
VC
are between 10
Ω and 100 Ω.
Copyright © 2012–2014, Texas Instruments Incorporated
33
Product Folder Links: