Texas Instruments UCD3138 Evaluation Module UCD3138OL64EVM-031 UCD3138OL64EVM-031 데이터 시트

제품 코드
UCD3138OL64EVM-031
다운로드
페이지 39
Test Procedure
7
Test Procedure
7.1
Download Firmware Codes to UCD3138OL64EVM-031
Set up the EVM connection based on
.
1. Set up the EVM connection based on
. The LED of USB adapter is lighted up.
2. Use provided jumper jump across J39. The LED of the EVM is lighted on.
3. Launch the UCD31xx device GUI following the steps described in
A window shown in
appears.
4. Check Download program flashDownload data flash and DO NOT write program checksum as
shown in
.
5. Click Firmware Download; then a new window appears as shown in
Click Select File and
browse an intended firmware code file with file extension .x0; then click Download. Click Close to exit
the download window.
6. After the firmware codes downloaded to the UCD3138 device, the intended test can be performed. In
this user’s guide, we use PWR031_Test_GPIO_ADC12.x0 to show how to use the board.
7.2
Example Test and Steps
1. Setup hyper terminal using RS232 serial port with the settings shown. Then launch the hyper terminal.
Figure 15. Hyper Terminal Settings
2. Place jumpers on the following headers, jump across J1 pin-11 and pin-13, i.e., J1(11 and 13), J2(2
and 3), J5(1 and 2), J18(1 and 2, 3 and 4, 5 and 6, 7 and 8, 9 and 10, 11 and 12, 13 and 14), J28(1
and 2), J29(1 and 2), J32(1 and 2).
3. Connect J36 all pins together using single-in-line connector; then use a click-wire, hook-wire connect
J36-1 and J30-4.
4. Place jumpers on J12(1 and 2), J16(1 and 2), J17(1 and 2), J20(2 and 3), J21(2 and 3).
19
SLUUA10 – October 2012
Using the UCD3138OL64EVM-031
Copyright © 2012, Texas Instruments Incorporated