Texas Instruments BQ24304 Evaluation Module for Li+ Charger and Front End Protection IC BQ24304EVM BQ24304EVM 데이터 시트

제품 코드
BQ24304EVM
다운로드
페이지 14
2.2.5
Wire Gauge
2.3
Equipment Setup
V
Power
Supply #1
Power
Supply #2
Load
#1
V
I
V
JMP8
U1
U2
APPLICATION CIRCUIT
JMP1 JMP2 JMP3 JMP4 JMP5 JMP6 JMP7
BAT+
BAT -
DC+
DC-
F
AUL
T
BA
T+
OUT
DC
-
J3
J2
J1
HPA245 BQ2430x/1x/8x DSG EVM
J4
DC
-
CHGIN
2.4
Procedure
2.4.1
CFE ENABLE and Voltage Regulation
Test Summary
www.ti.com
All wires connected to EVM input power supply and output load should use at least AWG 22. The
maximum current is up to 1 A.
A. Set the power supply #1 for 0 V
±
100 mVDC, 2
±
0.1-A current limit and then disable the output.
B. Connect the output of power supply #1 to J1 (DC+, DC–)
C. Connect a voltage meter across J1 (DC+, DC–).
D. Set the power supply #2 for 3.7 V
±
100 mVDC, 0.2
±
0.1-A current limit and then disable the output.
E. Connect power supply #2 to J2 (BAT+, DC–).
F. Connect a voltage meter across J2 (BAT+, DC–).
G. Connect the output of the Load #1 in series with a current meter (multimeter) to J2 (OUT, DC–).
Ensure that a voltage meter is connected across J2 (OUT, DC–). Turn on the power of the Load #1.
Set the load current to 0.2 A
±
50 mA but disable the output.
H. JMP1: ON, JMP2: ON, JMP3: ON, JMP4: ON, JMP5: ON, JMP6: ON, JMP7: ON, JMP8: OFF.
After the preceding steps, the test setup for HPA245 (bq2430x/1x/8x DSG EVM) is shown in
.
Figure 1. Original Test Setup for HPA245 (bq2430x/1x/8x DSG EVM)
1. Ensure that the preceding Equipment Setup steps are followed.
2. Enable output of PS#2.
3. Enable output of PS#1.
4. (For HPA245-001, -002, -003, -004, -009, -010, -013 only) Increase the output voltage of PS#1 to 6
V
±
0.1 V.
Measure
V(J2(OUT)) = 0 V
±
500 mV
Observe
D2 on, D3 off.
5. (For HPA245-005, -006, -007, -008, -011, -012 only) Increase the output voltage of PS#1 to 5 V
±
0.1
4
bq2430x/1x/8x DSG EVM (HPA245) for Li+ Charger Front-End Protection IC
SLUU291A – August 2007 – Revised April 2008