Texas Instruments Evaluation Module for BQ24212, 800mA, Single-Input, Single Cell Li-Ion Battery Solar Charger BQ24212EV BQ24212EVM-678 데이터 시트

제품 코드
BQ24212EVM-678
다운로드
페이지 13
BQ24210 EVM
HPA678
GND
J1
VBUS
J2
GND
BAT
APPLICATION CIRCUIT
U1
V
Iin
I
Power supply
#1
IBAT
V
Load #1
I
TS
PG
JP1
D1
LED
CHG
D2
J4
JP4
JP5
JP7
JP6
JP2
J3
JP3
Test Summary
2.2
Recommended Equipment for Testing
2.2.1
Power Supplies
Power Supply #1 (PS#1): a power supply capable of supplying 20 V at 1 A
2.2.2
Loads
A 20-V (or above), 1-A (or above) electronic load that can operate at constant current and constant
voltage mode or equivalent
2.2.3
Meters
Four Fluke 75 multimeters, (equivalent or better) or two equivalent voltage meters and two equivalent
current meters. The current meters must be capable of measuring 1 A + current.
2.3
Recommended Test Equipment Setup
1. Set the power supply #1 (PS#1) for 6.5 V
±
200 mVDC, 1-A
±
0.1-A current limit, and then turn off
supply.
2. Connect the output of PS#1 in series with a current meter (multimeter) to J1 (VBUS, GND).
3. Connect a voltage meter across J1 (VBUS, GND).
4. Connect Load #1 in series with a current meter to J2 (VBAT, GND). Turn off Load #1.
5. Connect a voltage meter across J2 (VBAT, GND).
6. Check all jumper shunts. JP1: OFF; JP2: OFF; JP3: OFF; JP4: OFF; JP5: connect 1-2 (External TS);
JP6: connect 2-3 (VBUS); JP7: connect 1-2 (charger OFF/ MODE high).
Figure 1. Original Test Setup for HPA678 (bq24210/2EVM)
5
SLUU477A
December 2010
Revised August 2011 800-mA, Single-Input, Single-Cell, Li-Ion Battery Solar Charger With Power Path
Copyright
©
2010
2011, Texas Instruments Incorporated