Texas Instruments Evaluation Module for BQ28550, Single Cell Li-Ion Battery Gas Gauge and Protection BQ28550EVM-001 BQ28550EVM-001 데이터 시트

제품 코드
BQ28550EVM-001
다운로드
페이지 19
Operation
Figure 8. Data Flash Screen, Safety Class
To read all the data from the bq28550 data flash, click on the menu option | Data Flash Read All |.
To write to a data flash location, click on the desired location, enter the data, and click Enter, which writes
the entire tab of flash data, or select the menu option | Data Flash Write All |. The data flash must be
read before any writes are performed to avoid any incorrect data being written to the device.
The | File Special Export | menu options allows the data flash to be exported, but it configures the
exported data flash to a learned state ready for mass production use.
The data flash configuration can be saved to a file by selecting | File Export | and entering a file name. A
data flash file also can be retrieved in this way, imported, and written to the bq28550 using the | Write All
| button.
The configuration information of the bq28550 and module calibration data are also held in the bq28550
data flash.
The bq28550 allows for an automatic data flash export function, similar to the SBS Data logging function.
This feature, when selected via | Options Auto Export |, exports data flash to a sequential series of files
named as FilenameNNNNN.gg, where N = a decimal number from 0 to 9.
The AutoExport interval is set under the | Options | menu with a minimum value of 15 s. The AutoExport
filename also is set under the | Options | menu.
When a check mark is next to | AutoExport |, the AutoExport is in progress. The same menu selection is
used to turn on/off AutoExport.
If the data flash screen is blank, then the bq28550 in use may not be supported by the bqEVSW version in
use. An upgrade may be required.
12
bq28550 Single Cell Li-Ion Battery Gas Gauge and Protection EVM
SLUU520
July 2011
Copyright
©
2011, Texas Instruments Incorporated