Texas Instruments BQ24018 (bqTINY) Evaluation Module BQ24018EVM BQ24018EVM 데이터 시트

제품 코드
BQ24018EVM
다운로드
페이지 9
www.ti.com
2.2.3
Procedure
3
Reference
4
Schematic, Physical Layouts, and Bill of Materials
Reference
1. Ensure that EQUIPMENT SETUP steps are followed. (switches should be in the closed position,
shunts installed, and power source set to 5.1 V/
±
0.1 VDC.) Turn on the power source.
2. Verify the red LED is lit.
3. Verify output voltage charges to 2.7
±
0.2V.
4. Open switch, SW2, and then close switch, SW2
5. Verify output voltage settles at 3.5
±
0.2V.
6. Verify that the input current is 0.73
±
0.08 Amps
7. Open switch, SW3
8. Verify that the input current is 0.13
±
0.03 Amps
9. Verify the output voltage, 4.360V
±
0.050 VDC
10. Open switch SW2.
11. Verify, with a scope (1V/div, 200ms/div), that the output charges to 4.4V
±
0.1V and discharges to
3.6V
±
0.5V at a frequency of 1Hz
±
0.5 Hz.
12. Verify that the LEDs flash between RED (D1) and GREEN (D2, mostly on green).
13. Close switch, SW2 and SW3 (all switches should be closed now) and power down supply.
14. EVM is good if all tests have passed. Remove I/O connections.
15. If there are more EVMs to test, loop back to 7.1 and continue until all units have been tested.
1. bq2401x data sheet (
)
This chapter contains the schematic diagram, the board layouts and assembly drawings, and the bill of
materials required for the EVM.
4
bq24018 (bqTINY™)
SLUU279 – August 2007