Texas Instruments CDCE949Perf-EVM - CDCE949 Performance Evaluation Module CDCE949PERF-EVM CDCE949PERF-EVM 데이터 시트

제품 코드
CDCE949PERF-EVM
다운로드
페이지 33
EEPROM
Xin/CLK
Xout
V
DD
GND
Vctr
V
DDOUT
VCXO
XO
LVCMOS
Y2
Y1
Y3
LV
CMOS
Pdiv1
10-Bit
Y4
Y5
Y6
Y7
Y8
Y9
LV
CMOS
Pdiv9
7-Bit
Pdiv8
7-Bit
M
8
M
9
LV
CMOS
LV
CMOS
Pdiv7
7-Bit
Pdiv6
7-Bit
M
6
M
7
LV
CMOS
LV
CMOS
Pdiv5
7-Bit
Pdiv4
7-Bit
M
4
M
5
LV
CMOS
LV
CMOS
Pdiv3
7-Bit
Pdiv2
7-Bit
M
2
M
3
LV
CMOS
Programming
and
SDA/SCL
Register
Input Clock
M
1
PLL Bypass
PLL 1
with SSC
M
U
X
1
PLL Bypass
PLL 2
with SSC
M
U
X
2
PLL Bypass
PLL 3
with SSC
M
U
X
3
PLL Bypass
PLL 4
with SSC
M
U
X
4
S0
S1/SDA
S2/SCL
www.ti.com
SCAS844D – AUGUST 2007 – REVISED MARCH 2010
FUNCTIONAL BLOCK DIAGRAM
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE
UNIT
V
DD
Supply voltage range
–0.5 to 2.5
V
V
I
Input voltage range
(2) (3)
–0.5 to V
DD
+ 0.5
V
V
O
Output voltage range
(2)
–0.5 to V
DDOUT
+ 0.5
V
I
I
Input current (V
I
< 0, V
I
> V
DD
)
20
mA
I
O
Continuous output current
50
mA
T
stg
Storage temperature range
–65 to 150
°C
T
J
Maximum junction temperature
125
°C
(1)
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions 
is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
(2)
The input and output negative voltage ratings may be exceeded if the input and output clamp–current ratings are observed.
(3)
SDA and SCL can go up to 3.6V as stated in the Recommended Operating Conditions table.
Copyright © 2007–2010, Texas Instruments Incorporated
3
Product Folder Link(s):