Texas Instruments LMP8646 Evaluation Board LMP8646EB/NOPB LMP8646EB/NOPB 데이터 시트

제품 코드
LMP8646EB/NOPB
다운로드
페이지 21
 
 
LMP8646EB User’s Guide 
 
 
 
November 2011 
                      Page 10 of 20 
 
 
              
 SNOU010 
For example, if Rg = 73 kOhm and the chosen bandwidth is 2 kHz, then the initial Cg value can be 
calculated as: 
 


nF
Cg
Hz
k
kOhm
Cg
Bandwidth
Rg
Cg
109
.
0
2
73
2
1
2
1
 
 
Once Cg is chosen, capture the output regulator current plot and adjust Cg to get the desired value. 
 
5.  Step 4: Choose the output resistor, ROUT, for LMP8646 
 
For the resistive load application, we found that ROUT plays a very small role in the performance.  
ROUT was important in the supercap application because it affects the initial current error.  Because 
current is directly proportional to voltage for a resistive load, the output current is not large at startup.  
In fact, the larger the ROUT, the longer it takes for the output voltage to reach its final value.  In our 
example, we chose a value of 2 kOhm for ROUT.   
 
6.  Step 5: Adjusting Components – capture the output current and output voltage plots and adjust the 
components as necessary.  The most common component to adjust is Cg for the bandwidth. 
 
A plot for the load current (yellow), output voltage of the LM3102 (pink) can be seen in Figure 6. 
 
 
Figure 6 – Plots for the Resistive Load Application