Texas Instruments AMC1203 Evaluation Module AMC1203EVM AMC1203EVM 데이터 시트

제품 코드
AMC1203EVM
다운로드
페이지 9
www.ti.com
BOM, Schematic, and Layout
5.2
Device Operation
Once the analog and digital power sources are applied to the AMC1203EVM, the digital outputs become
active. The AMC1203 is configured to use its onboard modulator clock. The internal reference of the
AMC1203 is used as the conversion reference.
Additionally, an analog input signal may be applied directly at screw terminal J1. See
and
for more details. The analog input range, (VIN+) – (VIN–), is ±320 mV.
As the input voltage approaches the maximum input level of +320mV, the 1s density of the modulator
output approaches 92%. Likewise, when the input voltage approaches the lower limit of –320 mV, the 1s
density is approximately 8%.
6
BOM, Schematic, and Layout
This section contains the complete bill of materials, schematic diagram, and PCB layout for the
AMC1203EVM.
NOTE:
Board layouts are not to scale. These are intended to show how the board is laid out; they
are not intended to be used for manufacturing AMC1203EVM PCBs.
6.1
Schematic
The AMC1203EVM schematic is appended to this document.
6.2
Printed Circuit Board Layout
Figure 3. AMC1203EVM Silk Screen Drawing
5
SBAU170 – August 2010
AMC1203EVM
Copyright © 2010, Texas Instruments Incorporated