Texas Instruments OPA2836 Evaluation Module for VSSOP/MSOP Package OPA2836IDGSEVM OPA2836IDGSEVM 데이터 시트

제품 코드
OPA2836IDGSEVM
다운로드
페이지 12
EVM Schematic, Layout, and Bill of Material (BOM)
2.1
Power Connections
The OPA2835DGS and OPA2836DGS EVMs are equipped with banana jacks for easy connection of
power. The positive supply input is labeled V
S
+. The Negative supply input is labeled V
S
. Ground is
labeled GND.
2.1.1
Split Supply Operation
To operate split supply, apply the positive supply voltage to V
S
+, negative supply voltage to V
S
, and the
ground reference from supply to GND.
2.1.2
Single Supply Operation
To operate single supply, jumper V
S
to GND and apply the positive supply voltage to V
S
+. Inputs and
outputs must be biased per data sheet specifications for proper operation.
2.2
Input and Output Connections
The OPA2835DGS and OPA2836DGS EVMs are equipped with SMA connectors for easy connection of
signal generators and analysis equipment. As shipped the EVMs are configure for non-inverting gain of 2
configuration and split supply with termination for connection to 50-
Ω
test equipment. For best results,
signals should be routed to and from the EVM with cables having 50-
Ω
characteristic impedance. See the
OPA2835 data sheet (
) and the OPA2836 data Sheet (
), and schematics and layouts
for details on how to reconfigure for other gain configurations.
3
EVM Schematic, Layout, and Bill of Material (BOM)
This section provides a complete schematic diagram, board layouts, and bill of materials for the
OPA2835DGS and OPA2836DGS EVMs.
2
OPA2835DGS, OPA2836DGS EVM
SLOU325
September 2011
Copyright
©
2011, Texas Instruments Incorporated