Texas Instruments AMC7812 Performance Demonstration Kit AMC7812EVM-PDK AMC7812EVM-PDK 데이터 시트

제품 코드
AMC7812EVM-PDK
다운로드
페이지 33
GUI Software and Operating Descriptions
The AMC and Alarms tab displays alarm information for the AMC Chip Temperature, D1 Temperature,
and D2 Temperature status. These indicators are highlighted with a yellow box in
Also
highlighted in
are false alarm protection settings for each alarm that can trigger with the
AMC7812; these settings allow the user to choose how many consecutive triggers must occur before the
alarm goes off. Additionally, at the bottom right of this tab, there is a window for enabling/disabling the
alarm pin function and alarm latch settings.
When an alarm occurs, the corresponding LED on the GUI lights up on the AMC7812EVM.
shows AMC Chip Temperature Status triggering for a low temperature, D1 temperature status triggering
for a high temperature, and D2 failing because jumper JP3 was removed to force a failure. The Global
Alarm LED is also triggered because of these alarms. Additionally, Alarm Status, highlighted in
red
at the
bottom right of
shows the value of the AMC Status Register.
Figure 7. AMC7812EVM-PDK Software GUI: Alarms Triggered
17
SBAU177A – September 2010 – Revised May 2013
AMC7812EVM-PDK User’s Guide
Copyright © 2010–2013, Texas Instruments Incorporated