Enable
Output = 100 mV/div
Enable
Output = 2 V/div
Zero Input Signal
1 V Input Signal, 2 V Output
Enable
Enable
Output 100 mV/div
Output 2 V/div
DRV604PWPEVM Performance
www.ti.com
6.6
Pop/Click (Enable)
Shown with and without input signal applied. The measurement results are presented in time domain.
Load 5 k
Ω
.
Power supply is applied, and then the shutdown signal is released. The enable signal is used to trigger the
measuring system.
Figure 13. Pop/Click (Enable)
6.7
Pop/Click (Disable)
Shown with and without input signal applied. The measurement results are presented in time domain.
Load 5 k
Ω
Figure 14. Pop/Click (Disable)