Texas Instruments DAC8564EVM - DAC8564 Evaluation Module DAC8564EVM DAC8564EVM 데이터 시트

제품 코드
DAC8564EVM
다운로드
페이지 27
3.4.4
Capacitive Load Drive
3.5
Jumper Setting
www.ti.com
EVM Operation
Table 6. Bipolar Output Operation Jumper Settings (continued)
Reference
Jumper
Function
Setting
JMP6
OPEN
Disconnect negative input of the operational amplifier from the gain resistor, R9.
JMP16
1-2
Connects the output terminal of the operational amplifier, U2, to J4A-5 for monitoring the voltage
output.
Another output configuration option is to drive a wide range of capacitive load requirement. However, all
operational amplifiers under certain conditions may become unstable depending on the operational
amplifier configuration, gain, and load value. These are just few factors that can affect operational
amplifiers stability performance and should be considered when implementing.
In unity gain, the OPA627 operational amplifier, U2, performs well with large capacitive loads. Increasing
the gain enhances the amplifier’s ability to drive even more capacitance, and by adding a load resistor,
even improves the capacitive load drive capability.
shows the jumper setting configuration for a capacitive load drive.
Table 7. Capacitive Load Drive Output Jumper Settings
Reference
Jumper
Function
Setting
JMP15
1-2
Connects DAC output (V
OUT
A) to the non-inverting input of the output operational amplifier, U2.
2-3
Connects DAC output (V
OUT
B) to the non-inverting input of the output operational amplifier, U2.
JMP5
OPEN
Connect V
REF
H to the inverting input of the operational amplifier, U2.
JMP10
1-2
Supplies power, V
SS
, to the negative rail of operational amplifier, U2, for wider range of operation.
JMP6
CLOSE
Connect the negative input of the operational amplifier, U2, to the gain resistor, R9.
JMP16
1-2
Connects the output terminal of the operational amplifier, U2, to J4A-5 for monitoring the voltage
output.
shows the function of each specific jumper setting of the EVM.
Table 8. Jumper Setting Function
Reference
Jumper
Function
Setting
JMP1
Connects ENABLE to IOVDD and allows the host controller to enable the DUT via J2A-8
Connects ENABLE to DGND and enables the DUT permanently.
JMP2
Connects LDAC to IOV
DD
and allows the host controller to update the DAC output using hardware
LDAC pin via J2A-2.
Connects LDAC to DGND and allows the DAC output to be updated by software LDAC.
JMP3
Connects A1 (for DAC8564EVM) to IOV
DD
and sets the address pin, A1 of the DAC8564EVM to
high (A1 = 1). Also allows the host controller to control A1 pin via J2A-14.
Connects RSTSEL (for DAC8565EVM) to IOV
DD
and sets the DAC8565 to reset to mid-scale. Also
allows the host controller to control the RSTSEL pin of the DUT via J2A-14.
Connects A1 (for DAC8564EVM) to DGND and sets the address pin, A1 of the DAC8564EVM to low
(A1 = 0).
Connects RSTSEL (for DAC8565EVM) to DGND and sets the DAC8565 to reset to minimum scale.
SLAU252 – June 2008
DAC8564/65 Evaluation Module
21