Texas Instruments DAC34SH84EVM - DAC34SH84 Evaluation Module DAC34SH84EVM DAC34SH84EVM 데이터 시트

제품 코드
DAC34SH84EVM
다운로드
페이지 29
Software Control
2.2.5
Register Control
Send All: Sends the register configuration to all devices
Read All: Reads register configuration from DAC348x device
Load Regs: Load a register file for all devices. Sample configuration files for common frequency plans
are located in the install directory: C:\Programs Files\Texas Instruments\DAC348x\EVM Configuration
File Released.
Select Load Regs button.
Double click on the EVM Configuration File Released folder and respective sub-folders for the
EVM.
Double click on the desired register file.
Click on Send All to ensure all of the values are loaded properly.
Save Regs: Saves the register configuration for all devices
2.2.6
Miscellaneous Settings
Reset USB: Toggle this button if the USB port is not responding. This generates a new USB handle
address
Note: It is recommended that the board be reset after every power cycle and the “reset usb” button
on the GUI be clicked.
Figure 7. USB Port Reset
Exit: Stops the program
10
DAC348x EVM
SLAU432 – February 2012
Copyright © 2012, Texas Instruments Incorporated