Texas Instruments TPS62260EVM-229 Evaluation Module TPS62260EVM-229 TPS62260EVM-229 데이터 시트

제품 코드
TPS62260EVM-229
다운로드
페이지 14
www.ti.com
2.1.10
J8 – GND – Converter 2
2.1.11
JP3 – ENABLE – Converter 2
3
Operation
4
Test Results
Enable
V
OUT
I
Load
Operation
This is the return connection for the output of converter 2.
This jumper enables or disables the converter. Connecting the shorting jumper between pins 1 and 2 (VIN
and EN) enables converter 2. Connecting the shorting jumper between pin 2 and 3 (EN and GND)
disables converter 2. Never leave this pin floating.
Connect the positive input power supply to J1 for converter number one or to J5 for converter number 2.
Connect the input power return (ground) to J2 for converter one or J6 for converter two. The
TPS622x0EVM-229 has an absolute maximum input voltage of 7 V. The recommended maximum
operating voltage is 6 V.
Connect the desired load between J3 and J4 for converter number one or between J7 and J8 for
converter number 2. The TPS62240EVM-229 can supply up to 300 mA of output current and the
TPS62260EVM-229 can supply up to 600 mA of output current.
Configure jumpers JP1, JP2, and JP3 as required. The functions of JP1, JP2, and JP3 are described in
the Set-up section of this manual.
This section provides typical performance waveforms for the TPS622X0EVM-229 printed-circuit board.
Figure 1. TPS62240 Start-up From Enable, Vin = 3 V, Vout = 1.8 V, ILoad = 300 mA
SLVU216 – July 2007
TPS622x0EVM-229
3