Max Expected Current
2
15
Max Expected Current
2
12
£ Current
LSB
£
Calibration Register =
0.00512
Current
R
LSB
SHUNT
´
INA231EVM Software Overview
5.2.4
Set Configuration Register
The Configuration Register must then be set correctly for the software to operate properly. There are two
methods used to set the Configuration Register: first, the user can manually calculate the desired value
and then input that value into the register table, as shown in
.Alternatively, the user can allow
the software to create a recommended window and choose an LSB for the current as shown in
Both methods accomplish the same goal by using
but the method is selected by changing the
value in Step 4: Select Configuration Method (as
and
show).
(1)
The current LSB is calculated by a recommended range in the INA231 data sheet as shown in
It is important to note that with either of the methods used, the Current LSB and the Calibration Register
values are calculated based on the other variable and the R
SHUNT
value. See the section, Programming the
INA231 in the
for more information on setting the Calibration Register value.
(2)
Figure 19. Setting the Configuration Register
Figure 20. Setting the Configuration Register (Current
(Calibration Register)
LSB)
5.2.5
Configuring the Alert Pin
The Alert Pin from the INA231 allows the user to set limits that monitor the registers and trigger a flag
when they are exceeded. The register that is being monitored can be changed by selecting the desired
alert configuration as shown in
The value that is being considered is compared to the Alert
Limit box. This Alert Limit box modifies its functionality based on the selected configuration. It is important
to note that by default, the INA231 Alert pin is set to active low.
Figure 21. Configuring the Alert Pin
17
SBOU128 – February 2013
INA231EVM Evaluation Board and Software Tutorial