Texas Instruments INA3221 Evaluation Module INA3221EVM INA3221EVM 데이터 시트

제품 코드
INA3221EVM
다운로드
페이지 26
INA3221EVM Software Overview
5.2.3
Graph Tab
The Graph tab, shown in
contains a plot window that shows the progression of data over time
on the INA3221. All seven variables at the bottom of the EVM software (CH1 V
SHUNT
, CH2 V
SHUNT
, CH3
V
SHUNT
, CH1 V
BUS
, CH2 V
BUS
, CH3 V
BUS
, and V
SHUNT
Sum) can be plotted using the drop-down box directly
above the graph. After the desired plot has been selected, toggle the Continuously Poll Data button
above the plot to begin polling for data. If the user desires to save the data from the plot, simply select the
USB Controls drop-down at the top of the page, then select the Start Graph Log option. When the Start
Graph Log 
is selected, the user is prompted to select a location for the data and to name the file.
Figure 17. Graphing INA3221 Data
5.2.4
Auto-Write and DVDD Voltage
The INA3221EVM software allows customization of the board level voltage, regulated by the SM-USB-
DIG. By selecting either 3.3 V or 5 V, the user can designate which voltage the device should operate at.
The software also includes an Auto-Write feature, as shown in
, which is enabled by default. This
feature automatically updates the register table whenever a change is made. When this feature is
enabled, the Write All Registers button serves little purpose and is only used as an alternative to when
this button is disabled.
Figure 18. Auto-Write, Power Button, and Voltage Control
17
SBOU126 – April 2012
INA3221EVM Evaluation Board and Software Tutorial
Copyright © 2012, Texas Instruments Incorporated