Texas Instruments LM21215A-1 Evaluation Board LM21215A-1EVM/NOPB LM21215A-1EVM/NOPB 데이터 시트

제품 코드
LM21215A-1EVM/NOPB
다운로드
페이지 15
Powering and Loading Considerations
3
Powering and Loading Considerations
Read this entire section prior to attempting to power the evaluation board.
3.1
Quick Setup Procedure
Step 1: Set the input source current limit to 10A. Turn off the input source. Connect the positive output of
the input source to V
IN
and the negative output to the corresponding GND.
Step 2: Connect the load (with 15A capability) to V
OUT
for the positive connection and GND for the
negative connection.
Step 3: The ENABLE pin should be left open for normal operation.
Step 4: Set the input source voltage to 5V. The load voltage should be in regulation with a nominal 1.2V
output.
Step 5: Slowly increase the load while monitoring the load voltage at V
OUT
. It should remain in regulation
with a nominal 1.2V output as the load is increased up to 15A.
Step 6: Slowly sweep the input source voltage from 2.95V to 5.5V. The load voltage should remain in
regulation with a nominal 1.2V output. If desired, the output of the device can be disabled by connecting
the ENABLE pin to GND.
3.2
Powering Up
It is suggested that the load power be kept low during the first power up. Once the device is powered up,
immediately check for 1.2V at the output.
A quick efficiency check is the best way to confirm that everything is operating properly. If something is
amiss you can be reasonably sure that it will affect the efficiency adversely. Few parameters can be
incorrect in a switching power supply without creating losses and potentially damaging heat.
Some voltage supplies can exhibit severe voltage overshoot during high current transients. If a supply
overshoots above 6.0V, damage to the LM21215 can occur. For these supplies, a large capacitor across
the terminals of the supply (1000µF) can alleviate this problem.
3.3
Over Current Protection
The LM21215 features a resistor-programmable current limit that allows the user to set the current limit to
any desired value between 4A and 20A by changing the resistor R
ILIM
. This evaluation board allows the
maximum possible current limit for the LM21215 by populating R
ILIM
with a 0
Ω
resistor. If the user desires
a lower current limit, the current limit should be set above the peak inductor current under maximum load
and ripple conditions to avoid a current limit event in normal operation. See
for details on how
to determine the R
ILIM
value.
4
Connection Descriptions
Table 1. Connection Descriptions
Terminal Silkscreen
Description
VIN
This terminal is the input voltage to the device. The evaluation board will operate over the input voltage
range of 2.95V to 5.5V.
GND
These terminals are the ground connections to the device. The input power ground should be connected
next to the input V
IN
connection, and the output power ground next to the V
OUT
connection.
VOUT
This terminal connects to the output voltage of the power supply and should be connected to the load.
ENABLE
This terminal connects to the enable pin of the device. This terminal can be left floating or driven
externally. If left floating, a 2µA current source will pull the pin high, thereby enabling the device. If driven
externally, a voltage typically less than 1.2V will disable the device.
SS/TRK
This terminal provides access to the SS/TRK pin of the device. Connections to this terminal are not
needed for most applications. The feedback pin of the device will track the voltage on the SS/TRK pin if
it is driven with an external voltage source that is below the 0.6V reference.
2
AN-2130 LM21215 Evaluation Board
SNVA476A – March 2011 – Revised May 2013
Copyright © 2011–2013, Texas Instruments Incorporated