Texas Instruments TSC2111 Evaluation Module TSC2111EVM TSC2111EVM 데이터 시트

제품 코드
TSC2111EVM
다운로드
페이지 39
www.ti.com
Program Description
3.2.2
Buffer Function
In the middle of the screen are the Buffer Mode settings. By default, the buffer function is disabled, and all
touch or non-touch data are converted and stored to the corresponding registers. When the buffer function
is enabled by checking the Enable option, the data is converted and saved to the buffer registers in Page
3 of the TSC2111 memory space. Refer to the data sheet for the details of the buffer function.
Below the Buffer Trigger slider, the Read Buffer for Touch Screen Data button can be used to place the
TSC2111 into self-controlled mode, and the Read Buffer for Non Touch Screen Data button can be used
to select host-controlled mode.
When the Read Buffer for Touch Screen Data button is clicked, the interface switches from this screen to
the Human Interface screen. The touch-screen data in the TSC2111 page 3 registers is displayed in the
Buffer Contents box when the screen is touched, as
illustrates. Note that in buffer mode, the
touch screen data does not show up on the touch screen drawing box. In XY A/D mode, the data list is in
the sequence of X, Y, X, Y, X, Y, etc. And under the XYZ A/D mode, the data is that of X, Y, Z1, Z2, X, Y,
Z1, Z2, X, etc.
Figure 6. Human Interface Screen With Enabled Buffer Function
Clicking on the Read Buffer for Non Touch Screen Data button places the TSC2111 in auto-scan mode.
This automatically scans the AUX1, AUX2, and TEMP1 inputs, and displays nontouch screen raw data in
the Reading Content box on the right side of the display under the Data Acquisition tab, as shown in
The data in the Reading Content box shown in
is listed in this order: AUX1, AUX2,
TEMP1, AUX1, AUX2, TEMP1, AUX1, etc.
SLAU178 – April 2006
TSC2111EVM and TSC2111EVM-PDK
11