Texas Instruments CC2650DK 사용자 설명서

다운로드
페이지 1570
AUX – Sensor Controller Registers
17.8.4.10 RECHARGECFG Register (Offset = 30h) [reset = X]
RECHARGECFG is shown in
and described in
.
Recharge Controller Configuration This register sets all relevant patameters for controlling the recharge
algorithm.
Figure 17-45. RECHARGECFG Register
31
30
29
28
27
26
25
24
ADAPTIVE_EN
RESERVED
R/W-X
R-X
23
22
21
20
19
18
17
16
C2
C1
R/W-X
R/W-X
15
14
13
12
11
10
9
8
MAX_PER_M
MAX_PER_E
R/W-X
R/W-X
7
6
5
4
3
2
1
0
PER_M
PER_E
R/W-X
R/W-X
Table 17-66. RECHARGECFG Register Field Descriptions
Bit
Field
Type
Reset
Description
31
ADAPTIVE_EN
R/W
X
Enable adaptive recharge Note: Recharge can be turned completely
of by setting MAX_PER_E=7 and MAX_PER_M=31 and this bitfield
to 0
30-24
RESERVED
R
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
23-20
C2
R/W
X
Gain factor for adaptive recharge algorithm period_new=period * (
1+/-(2^-C1+2^-C2) ) Valid values for C2 is 2 to 10 Note: Rounding
may cause adaptive recharge not to start for very small values of
both Gain and Initial period. Criteria for algorithm to start is
MAX(PERIOD*2^-C1,PERIOD*2^-C2) >= 1
19-16
C1
R/W
X
Gain factor for adaptive recharge algorithm period_new=period * (
1+/-(2^-C1+2^-C2) ) Valid values for C1 is 1 to 10 Note: Rounding
may cause adaptive recharge not to start for very small values of
both Gain and Initial period. Criteria for algorithm to start is
MAX(PERIOD*2^-C1,PERIOD*2^-C2) >= 1
15-11
MAX_PER_M
R/W
X
This register defines the maximum period that the recharge
algorithm can take, i.e. it defines the maximum number of cycles
between 2 recharges. The maximum number of cycles is specified
with a 5 bit mantissa and 3 bit exponent:
MAXCYCLES=(MAX_PER_M*16+15)*2^MAX_PER_E This field sets
the mantissa of MAXCYCLES
10-8
MAX_PER_E
R/W
X
This register defines the maximum period that the recharge
algorithm can take, i.e. it defines the maximum number of cycles
between 2 recharges. The maximum number of cycles is specified
with a 5 bit mantissa and 3 bit exponent:
MAXCYCLES=(MAX_PER_M*16+15)*2^MAX_PER_E This field sets
the exponent MAXCYCLES
7-3
PER_M
R/W
X
Number of 32 KHz clocks between activation of recharge controller
For recharge algorithm, PERIOD is the initial period when entering
powerdown mode. The adaptive recharge algorithm will not change
this register PERIOD will effectively be a 16 bit value coded in a 5 bit
mantissa and 3 bit exponent: This field sets the Mantissa of the
Period. PERIOD=(PER_M*16+15)*2^PER_E
1267
SWCU117A – February 2015 – Revised March 2015
AUX – Sensor Controller with Digital and Analog Peripherals