Texas Instruments CC2650DK 사용자 설명서

다운로드
페이지 1570
Customer Configuration (CCFG)
9.1.1.1
MODE_CONF_1 Register (Offset = FACh) [reset = FFFBFFFFh]
MODE_CONF_1 is shown in
and described in
.
Mode Configuration 1
Figure 9-1. MODE_CONF_1 Register
31
30
29
28
27
26
25
24
RESERVED
EXT_32KHZ_CLK_DIO
R/W-3h
R/W-3Fh
23
22
21
20
19
18
17
16
ALT_DCDC_VMIN
ALT_DCDC_DI
ALT_DCDC_IPEAK
THER_EN
R/W-Fh
R/W-1h
R/W-3h
15
14
13
12
11
10
9
8
DELTA_IBIAS_INIT
DELTA_IBIAS_OFFSET
R/W-Fh
R/W-Fh
7
6
5
4
3
2
1
0
XOSC_MAX_START
R/W-FFh
Table 9-2. MODE_CONF_1 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-30
RESERVED
R/W
3h
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
29-24
EXT_32KHZ_CLK_DIO
R/W
3Fh
Unsigned integer, selects which DIO is used to supply external
32kHz clock for SCLK_LF when MODE_CONF.SCLK_LF_OPTION
is set to EXTERNAL. DIO configuration must not be overwritten by
any other system drivers.
23-20
ALT_DCDC_VMIN
R/W
Fh
Minimum voltage for when DC/DC should be used if alternate
DC/DC setting is enabled
(SIZE_AND_DIS_FLAGS.DIS_ALT_DCDC_SETTING=0). Voltage =
(28 + ALT_DCDC_VMIN) / 16. 0: 1.75V 1: 1.8125V ... 14: 2.625V
15: 2.6875V NOTE! The DriverLib function
SysCtrl_DCDC_VoltageConditionalControl() must be called regularly
to apply this field (handled automatically if using TI RTOS!).
19
ALT_DCDC_DITHER_EN
R/W
1h
Enable DC/DC dithering if alternate DC/DC setting is enabled
(SIZE_AND_DIS_FLAGS.DIS_ALT_DCDC_SETTING=0). 0: Dither
disable 1: Dither enable
18-16
ALT_DCDC_IPEAK
R/W
3h
Inductor peak current if alternate DC/DC setting is enabled
(SIZE_AND_DIS_FLAGS.DIS_ALT_DCDC_SETTING=0). Assuming
10uH external inductor! Peak current = 31 + ( 4 *
ALT_DCDC_IPEAK ) : 0: 31mA (min) ... 4: 47mA ... 7: 59mA (max)
15-12
DELTA_IBIAS_INIT
R/W
Fh
Signed delta value for IBIAS_INIT. Delta value only applies if
SIZE_AND_DIS_FLAGS.DIS_XOSC_OVR=0. See
FCFG1:AMPCOMP_CTRL1.IBIAS_INIT
11-8
DELTA_IBIAS_OFFSET
R/W
Fh
Signed delta value for IBIAS_OFFSET. Delta value only applies if
SIZE_AND_DIS_FLAGS.DIS_XOSC_OVR=0. See
FCFG1:AMPCOMP_CTRL1.IBIAS_OFFSET
7-0
XOSC_MAX_START
R/W
FFh
Unsigned value of maximum XOSC startup time (worst case) in units
of 100us. Value only applies if
SIZE_AND_DIS_FLAGS.DIS_XOSC_OVR=0.
688
Device Configuration
SWCU117A – February 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated