Calibration Screen
To write to a data flash location, click on the desired location, enter the data and press Enter, which writes
the entire tab of flash data, or select menu option | Data Flash Write All |. The data flash must be read
before any writes are performed to avoid any incorrect data being written to the device.
The | File Special Export | menu option allows the data flash to be exported, but it configures the
exported data flash to a learned state ready for mass production use.
The data flash configuration can be saved to a file by selecting | File Export | and entering a file name. A
data flash file also can be retrieved in this way, imported, and written to the bq20z655 and bq34z651
using the | Write All | button.
The configuration information of the bq20z655 and bq34z651 and module calibration data also is held in
the bq20z655 and bq34z651 data flash.
The bq20z655 and bq34z651 allows for an automatic data flash export function, similar to the SBS Data
logging function. This feature, when selected via | Options Auto Export |, exports Data Flash to a
sequential series of files named as FilenameNNNNN.gg where N = a decimal number from 0 to 9.
The AutoExport interval is set under the | Options menu | with a minimum value of 15 s. The AutoExport
filename also is set under the | Options menu |.
When a checkmark is next to | AutoExport |, the AutoExport is in progress. The same menu selection is
used to turn on/off AutoExport.
If the data flash screen is blank, then the bq20z655 and bq34z651 that is being used may not be
supported by the bqEVSW version that is being used. An upgrade may be required.
9
Calibration Screen
9.1
How to Calibrate
The bq20z655 and bq34z651 must be calibrated using power supplies or a power supply and cell
simulation resistors (200
Ω
to 1000
Ω
each) before cells are attached. Before the bq20z655 and bq34z651
are calibrated:
Connect and measure a 2-A current source from 1N (
) and PACK
(+) to calibrate without using the
FETs. (Calibration using the FETs is not recommended.)
Measure the pack voltage from Batt+ to Batt
(total of cell voltages).
Measure the temperature of the pack.
These steps may not be required, depending on the type of calibration being performed.
9.2
To Calibrate the bq20z655 and bq34z651
To calibrate the bq20z655 and bq34z651, perform the following steps.
1. Select the types of calibration to be performed (see
).
2. Enter the measured values for the types selected (except for CC Offset Calibration).
3. If Voltage Calibration is selected, then enter the number of cells on the pack.
4. If Temperature Calibration is selected, then select the sensor that is to be calibrated.
5. If the current source is connected between 1N and PACK
, then select the Off (bypassed) check box
in the FET Control section.
6. Press the Calibrate Part button.
9.3
Board Offset Calibration
To perform the offset calibration for the current offset of the board, do these steps:
1. Remove load/external voltage and short PACK
to Batt
.
2. Press the CC Board Offset Calibration button.
12
bq20z655EVM and bq34z651EVM SBS 1.1 Impedance Track
SLUU697
November 2011
Technology-Enabled Evaluation Module