Quick Setup Guide
www.ti.com
2.2
Unpacking the EVM
Upon opening the TAS5631PHD2EVM package, check to make sure that the following items are included:
1 pc. TAS5631PHD2EVM board using one TAS5518PAG and one TAS5631PHD.
1 pc. TI Input-USB board 2 for interfacing TAS5631PHD2EVM with SPDIF/analog sources and PC for
control.
1 pc. Signal and Control Interface IDC cable for connection to an I
2
S front-end like the attached TI
Input-USB board 2.
1 pc. Cable for connecting Input-USB board 2 to a USB port on a PC for TAS5518 control by software.
1 pc. AC to DC External 15 V Power supply (System supply).
4 pcs. AC Input Clips for External 15 V Power Supply (US, Europe, UK and Australia).
If any of these items are missing, contact the nearest Texas Instruments Product Information Center to
inquire about a replacement.
Connect the Input-micro board 2 to the TAS5631PHD2EVM using the delivered IDC cable.
2.3
Power Supply Setup
To power up the EVM, two power supplies are needed. One for system power, logic and gate-drive, and
one for output stage supply. H-bridge Power supply is connected to the EVM using banana cables.
System Power Supply is supplied from the enclosed External 15 V wall plug adapter.
Table 2. Recommended Supply Voltages
Description
Voltage Range
Current Requirements
Cable
Output stage power supply
25 – 50 V
16 A
J15 (marked +50V)
CAUTION
Applying voltages above the specifications given in
can cause
permenant damage to the hardware.
NOTE:
The length of power supply cable must be minimized. Increasing length of PSU cable is
equal to increasing the distortion for the amplifier at high output levels and low frequencies.
2.4
Speaker Connection
CAUTION
Both positive and negative speaker outputs are floating and cannot be
connected to ground (e.g. through an oscilloscope).
2.5
Output Configuration BTL and PBTL
When changing mode e.g. from BTL to PBTL, make sure that RESET is activated before changing the
state of mode switches SW1 and SW2. Switch SW1 and SW2 has to be synchronized in state BTL or
PBTL.
In PBTL mode the load has to be connected according to
:
6
TAS5631PHD2EVM
SLOU275A – December 2009 – Revised May 2010
Copyright © 2009–2010, Texas Instruments Incorporated