Texas Instruments High Performance Dual Output Synchronous Buck Evaluation Module using the TPS51220A TPS51220AEVM-476 TPS51220AEVM-476 데이터 시트

제품 코드
TPS51220AEVM-476
다운로드
페이지 23
V1
V3
V4
V5
V6
12V/10A
DC Power
Source
+
-
V2
Electronic
Load #2.
3.3V/8A
+
-
Electronic
Load #1.
5V/8A
+
-
TP7
(TP8)
TP2
(TP3)
Metal Ground
Barrel
Probe Tip
Test Setup
5
Test Setup
5.1
Test Equipment
Voltage Source: The power source must be capable of supplying 8 VDC to 20 VDC at up to 10 A.
Multimeters: A minimum of three voltage meters are required. Other voltage meters can be used to
monitor some of the test points.
Output Load: Two constant current electronic loads are recommended. They must be able to sink up to
10 A when the output is 3.3 V or 5V.
Oscilloscope: A minimum 50-MHz digital oscilloscope and a voltage probe is required. The scope can be
used to measure output ripple and monitor some of the test points
Fan: A fan is not required when testing the EVM
Recommended Wire Gauge: Both loads and input should be connected using a minimum gauge wire of
AWG#16. Also these connections should be kept as short as possible.
5.2
Recommended Test Setup
Figure 2. TPS51220A EVM-476 Recommended Test Set Up
Figure 3. Recommended
Tip and Barrel
Technique to Measure Output Ripple Voltage
6