Texas Instruments INA226 Evaluation Module INA226EVM INA226EVM 데이터 시트

제품 코드
INA226EVM
다운로드
페이지 27
INA226EVM Hardware
3.6.4
External I
2
C Lines and Terminal Block T1
The I
2
C communication lines on the INA226EVM are tied to two sources: the internal I
2
C communication
lines from the SM-USB-DIG and the terminal block T1. If the user wants to add external signals separate
from the SM-USB-DIG, simply disconnect the SM-USB-DIG from the INA226EVM board and hook up the
necessary SDA, SCL, and GND lines. Also, remember to apply an external supply to the lines that is
compatible with the I
2
C communication device being used.
NOTE:
Failure to disconnect the SM-USB-DIG while using external I
2
C communication can cause
damage to the SM-USB-DIG or any external communication devices that are connected.
3.6.5
VIN+/VIN
Input filter (R1, R2, and C1)
The INA226EVM has an optional input filter to remove high-frequency noise from the inputs VIN+ and
VIN
. This filter is typically unpopulated. The default values for R1 and R2 are 0-
Ω
resistors.
shows the typical setup, which is recommended for basic INA226 evaluation.
Figure 9. Typical Filter Setup
11
SBOU113
June 2011
INA226EVM Evaluation Board and Software Tutorial
Copyright
©
2011, Texas Instruments Incorporated