2.2
Jumpers
2.3
Test Points
2.4
Voltage Reference
www.ti.com
Hardware Overview
The UCD9081EVM operation can be configured using jumpers:
Onboard or external power supply voltage monitoring
Onboard or external power supply enabling
Setting of the I
2
C address for the system
Creating undervoltage faults for the onboard power supplies
See
for descriptions and default settings for the jumpers on the UCD9081EVM.
Table 1. UCD9081 Jumpers
Number
Function
Default Setting
JP1–JP8
Power supply monitoring through onboard power supplies or externally connected.
Pins 1-2 (onboard
Connect to pins 1-2 for monitoring onboard supplies and pins 2-3 for external supplies via
supplies)
connector J4.
JP9–JP16
Power supply enable signal configuration ( pullup or pulldown). Enable pins for each of
Pins 1-2 (pullup to 3.3 V
the channels can be either pulled up to 3.3 V or down to ground to support power
for active-low supply
supplies that have either active-high or active-low enables. Connect to pins 1-2 for pulling
enables).
up to 3.3 V and connect to pins 2-3 for pulling down to ground.
JP17–JP20
I
2
C address detection. Four digital signals on the UCD9081 are sampled at start-up to
Pins 2-3 (pulldown to
determine its I
2
C address. These four jumpers control, if the signals are pulled up to 3.3 V
ground for all zero).
or down to ground. Connect to pins 1-2 for 3.3 V and connect to pins 2-3 for ground.
JP21–JP28
Undervoltage fault. For each rail, you can generate an undervoltage fault by removing this Jumper on pins 1-2 for
jumper. Removal of these jumpers removes input from the power supplies, causing the
no undervoltage fault.
output voltage being monitored by the UCD9081 to fall below the configured undervoltage
threshold. If the UV threshold is zero, no undervoltage occurs.
JP29
EN8 shared with I
2
C address detection. Can be used to disconnect RAIL8 enable from
Jumper on pins 1-2.
the UCD9081.
The UCD9081EVM provides test points that can be used for evaluation. Important voltages can be
monitored with a meter through the use of the test points.
The UCD9081 can operate with either the internal voltage reference or an external voltage reference
selectable using the GUI. Voltage reference selection depends on the monitoring accuracy required. The
UCD9081EVM provides an accurate external reference to the V
CC
pin of the UCD9081. When operating
with the internally generated 2.5-V reference, the monitoring accuracy depends on the accuracy of the
internal voltage reference (see data sheet
for details).
The default behavior of the device (and the EVM) is for an external voltage reference.
SLVU249 – September 2008
UCD9081 Power Supply Sequencer and Monitor EVM
5