Calibrate Screen
If the Data Flash screen is blank, then the bq27425 that is being used may not be supported by the
bqEVSW version that is being used. An bqEVSW upgrade may be required.
9
Calibrate Screen
To ensure proper calibration, perform the following steps. These steps may or may not be required,
depending on the type of calibration being performed. Only one calibration item can be selected and
calibrated at once.
9.1
To Calibrate the bq27425
1. Select the types of calibration to be performed (see
).
2. Enter the measured values for the types selected.
3. Press the button to calibrate.
9.2
Coulomb Counter Offset Calibration
This performs the internal calibration of the coulomb counter input offset.
9.3
Board Offset Calibration
This performs the offset calibration for the current offset of the board.
It is expected that no current is flowing through the sense resistor while performing this calibration step.
1. Remove load and short PACK– to LOAD–.
2. Press the Calibrate Board Offset button.
9.4
Voltage Calibration
Voltage calibration usually is not required. If needed, follow these steps:
1. Measure the voltage across Pack+ and Pack–.
2. Type the voltage value in mV into Enter Actual Voltage.
3. Press the Calibrate Part as indicated below button.
9.5
Temperature Calibration
Temperature calibration usually is not required. If needed, follow these steps:
1. Measure the temperature for PACK.
2. Type the temperature value into Enter Actual Temperature.
3. Select if the temperature sensor to calibrate is the internal or external.
4. Press the Calibrate Voltage and Current as indicated below button.
9.6
Pack Current Calibration
1. Connect a load to LOAD– and LOAD+ that draws approximately 1 A, or connect a current source to
LOAD– and Pack–.
2. Measure the current and type value into Enter Actual Current using (–) for current in discharge
direction.
3. Press the Calibrate Pack Current as indicated below button.