Texas Instruments BQ24157EVM-697 Evaluation Module BQ24157EVM-697 BQ24157EVM-697 데이터 시트

제품 코드
BQ24157EVM-697
다운로드
페이지 18
To
Computer
USB port
USB
Interface
Adapter
I/O
USB
T
exasInstruments
©2006
10-pin
Ribbon
Cable
To EVM
Test Summary
2.2.4
Meters
Two equivalent voltage meters and two equivalent current meters. The current meters must be able to
measure 2-A current.
2.2.5
Computer
A computer with at least one USB port and a USB cable. The bq24153_6_8 evaluation software must be
properly installed.
2.2.6
HPA172 Communication Kit (USB TO GPIO)
A HPA172 USB to I2C communication kit.
2.2.7
Software
Download BQ24153_6_8Setup.zip from the charger's product folder, unzip the file and double-click on the
“SETUP.EXE” file. Follow the installation steps.
2.3
Recommended Test Equipment Setup
1. Set Power Supply #1 for 5 V ± 100 mVdc, 2-A. ±0.1-A current limit, and then turn off supply.
2. Connect the output of Power Supply #1 in series with a current meter (multimeter) to J1 (DC+, DC–).
3. Connect a voltage meter across J1 (DC+, DC–).
4. Connect the Load #2 in series with a current meter (multimeter) to J2 (BAT+, BAT–). Ensure that a
voltage meter is connected across J2 (BAT+, BAT–). Turn on the Load #2. Use the constant voltage
mode. Set the output voltage to 2.5 V.
5. Turn off Load #2.
6. Connect J5 to HPA172 kit by the 10-pin ribbon cable. Connect the USB port of the HPA172 kit to the
USB port of the computer. The connections are shown in
.
Figure 1. Connections of HPA172 Kit
7. Install jumpers per
Table 1. Factory Jumper Settings
Spin
JMP1
JMP2
JMP3
JMP4
JMP5
HPA256-001
(-LED-) ON
(-LO-) ON
OFF
(-LO-) ON
ON
(bq24153A)
HPA256-002
(-LED-) ON
(-HI-) ON
OFF
(-LO-) ON
ON
(bq24156A)
4
bq24153A/56A/57/58/59 Fully Integrated, Switch-Mode, One-Cell, Li-Ion ChargerSLUU453B – November 2010 – Revised September 2012
With Full USB Compliance and USB-OTG Support EVM
Copyright © 2010–2012, Texas Instruments Incorporated