Test Setup and Results
2.1
Input / Output Connections
Test Setup and Results
www.ti.com
This section describes how to properly connect, set up, and use the TPS54418EVM-375 evaluation
module. The section also includes test results typical for the evaluation module and covers efficiency,
output voltage regulation, load transients, loop response, output ripple, input ripple, and start-up.
The TPS54418EVM-375 is provided with input/output connectors and test points as shown in
. A
power supply capable of supplying 3 A must be connected to J1 through a pair of 20 AWG wires. The load
must be connected to J4 through a pair of 20 AWG wires. The maximum load current capability must be at
least 4 A to use the full capability of this EVM. Wire lengths must be minimized to reduce losses in the
wires. Test-point TP1 provides a place to monitor the V
IN
input voltages with TP2 providing a convenient
ground reference. TP6 is used to monitor the output voltage with TP7 as the ground reference.
Table 4. EVM Connectors and Test Points
Reference Designator
Function
J1
V
IN
(see
for V
IN
range).
J2
2-pin header for enable. Connect EN to ground to disable, open to enable.
J3
2-pin header for to allow pull up of PWRGD to V
IN
.
J4
V
OUT
, 1.8 V at 4 A maximum.
TP1
V
IN
test point at V
IN
connector.
TP2
GND test point at V
IN
.
TP3
PH test point
TP4
Slow start monitor test point.
TP5
Test point between voltage divider network and output. Used for loop response measurements.
TP6
Output voltage test point at OUT connector.
TP7
GND test point at OUT connector.
4
TPS54418EVM-375 4-A, SWIFT™ Regulator Evaluation Module