Texas Instruments TSC2017 Performance Demonstration Kit TSC2017EVM-PDK TSC2017EVM-PDK 데이터 시트

제품 코드
TSC2017EVM-PDK
다운로드
페이지 20
www.ti.com
EVM-PDK Operation
Note that the I
2
C Bus Status shown in the lower right corner (just above the STOP button of the GUI in
is
green
if the driver in your PC has been properly set up, and the TSC slave address is
corresponding.
TSC2017 has an address pin A0 that can be set low or high to get the TSC2017 address for either
1001000b (if A0 = low) or 1001001b (if A0 = high). On the TSC2017EVM board, JP3 controls the A0
status. By default, A0 must be installed (refer to
), and thus the default A0 is '0' in the Device
Address (A0) selection box. Change it to '1' if TSC2017EVM JP3 is removed (high).
At the startup of the GUI, the non-Touch Data Acquisition section (on the right side) functions and proper
temperature data is displayed, as shown in
To stop running the software, you click on the STOP button in the lower right corner of the screen.
6.3
GUI and Operation Description
After the TSC2017EVM-PDK hardware and software installation and setup (described in Section 6.1),
evaluation and development with the TSC2017 can begin.
By plugging into a USB port on your PC and starting the TSC2017EVM-PDK software on your PC, the
interface GUI is displayed as shown in
.
The GUI has four general sections (shown in
):
1. The yellow boxes contain Touchscreen Functions.
2. The blue box contains Data Acquisition Functions.
3. The pink box contains TSC2017 commands.
4. The purple box contains TSC2017 Setup commands.
9
SLAU305A – January 2010 – Revised June 2010
TSC2017EVM and TSC2017EVM-PDK
Copyright © 2010, Texas Instruments Incorporated