www.ti.com
Test Procedure
6
Test Procedure
All tests should use the set up as described in
of this user’s guide. The following test procedure
is recommended primarily for power up and shutting down the evaluation module. Never leave a powered
EVM unattended for any length of time.
6.1
Applying Power to the EVM
1. Set up the EVM as shown in
of this user’s guide.
(a) If no-load input power measurements are to be made, set the power analyzer to long averaging and
external shunt mode. Insert a shunt, such as a 10-
Ω
resistor as shown in
in series with
the Neutral terminal of the EVM. Set the appropriate current scale on the power analyzer.
(b) For operation with a load, as shown in
, set the electronic load to constant current mode to
sink 0 A.
2. Prior to turning on the AC source, set the voltage to between 85 V
AC
and 265 V
AC
.
3. Turn on the AC source.
4. Monitor the output voltage on DMM V1.
5. Monitor the output current on DMM A1.
6. The EVM is now ready for testing.
6.2
No-Load Power Consumption
1. Use the test set up shown in
(a) Set the power analyzer to external shunt mode.
(b) Set the appropriate current scale factor for using an external shunt on the power analyzer. A 10-
Ω
shunt scales at 10,000 mV/A for the PM100 Voltech.
(c) Set the power analyzer long averaging time to include several cycles of operation. The PM100
Voltech should be set to a long averaging time of 10 or more for accurate Burst Mode
measurements.
2. Apply power to the EVM per
3. Monitor the input power on the power analyzer while varying the input voltage.
4. Make sure the input power is off and the bulk capacitor and output capacitors are completely
discharged before handling the EVM.
6.3
Output Voltage Regulation and Efficiency
1. For load regulation:
(a) Use the test set up shown in
(i) Be sure to remove the external shunt from the power analyzer and set the analyzer to normal
mode (not long averaging).
(b) Set the AC source to a constant voltage between 85 V
AC
and 265 V
AC
.
(c) Apply power to the EVM per
.
(d) Vary the load current from 0 A up to 5 A, as measured on DMM A1.
(e) Observe that the output voltage on DMM V1 remains within 15% of 5 V
DC
.
2. For line regulation:
(a) Set the load to sink 5 A.
(b) Vary the AC source from 85 V
AC
to 265 V
AC
.
(c) Observe that the output voltage on DMM V1 remains within 15% of 5 V
DC
.
3. Make sure the input power is off and the bulk capacitor and output capacitors are completely
discharged before handling the EVM.
11
SLUU434 – August 2010
5-V, 25-W Flyback Converter With Secondary-Side Synchronous Rectification
Copyright © 2010, Texas Instruments Incorporated