TEST SET UP 
3.4 EQUIPMENT 
3.4.1 VOLTAGE SOURCE 
V
12V_IN
  
The input voltage source (V
12V_IN
) should be a 0-15V variable DC source capable of 5Adc.  Connect V
12V_IN
  to  J1 
as shown in Figure 3. 
3.4.2 METERS 
A1: 0-5Adc, ammeter  
V1: V
12V_IN
, 0-15V voltmeter  
V2: V
1V5_OUT
 0-5V voltmeter 
3.4.3 LOADS 
LOAD1 
The Output Load (LOAD1) should be an Electronic Constant Current Mode Load capable of 0-15Adc @ 1.5V 
3.4.4 OSCILLOSCOPE 
OSCILLOSCOPE 
A Digital or Analog Oscilloscope can be used to measure the ripple voltage on V
OUT
.  The Oscilloscope should be 
set for 1M
Ω impedance, 20MHz Bandwidth, AC coupling, 1μs/division horizontal resolution, 20mV/division vertical 
resolution for taking output ripple measurements.  TP 9 and TP 10 can be used to measure the output ripple 
voltage by placing the oscilloscope probe tip through TP 9 and holding the ground barrel to TP 10 as shown in 
Figure 3.  For a hands free approach, the loop in TP 10 can be cut and opened to cradle the probe barrel.  Using 
a leaded ground connection may induce additional noise due to the large ground loop area. 
3.4.5  Recommended Wire Gauge 
V
12V_IN
 to J1 
The connection between the source voltage, V
12V_IN
 and J1 of the TPS40190EVM-001 can carry as much as 3 
Adc.  The minimum recommended wire size is AWG #16 with the total length of wire less than 4 feet (2 feet input, 
2 feet return). 
J2 to LOAD1 (Power) 
The power connection between J2 of TPS40190EVM-001 and LOAD1 can carry as much as 15Adc.  The 
minimum recommended wire size is 2x AWG #16, with the total length of wire less than 4 feet (2 feet output, 2 
feet return). 
3.4.6 OTHER 
FAN 
This evaluation module includes components that can get hot to the touch, because this EVM is not enclosed to 
allow probing of circuit nodes, a small fan capable of 200-400 lfm is required to reduce component surface 
temperatures to prevent user injury.  The EVM should not be left unattended while powered.  The EVM should not 
be probed while the fan is not running. 
3.5 EQUIPMENT SETUP 
Shown in Figure 3 is the basic test set up recommended to evaluate the TPS40190EVM-001.  Please note that 
although the return for J1 and J2 are the same, the connections should remain separate as shown in Figure 2.