Texas Instruments INA216 Evaluation Module INA216EVM INA216EVM 데이터 시트

제품 코드
INA216EVM
다운로드
페이지 17
+
Load
INA216DIP
INA216EVM
V
OUT
GND
C
1
R
3
R
4
R
1/
2
R
I
S
V
IN
-
V
IN+
Quick Start Setup and Use
2
Quick Start Setup and Use
Follow these procedures to set up and use the INA216EVM.
Step 1. Insert the device board to be evaluated into the U1 location. The U1 location allows the user
to interchange device boards to evaluate the impact of implementing various gains in the
design.
Step 2. Connect the INA216 input pins to both the common-mode source as well as the load. The
INA216 derives its supply voltage from the VIN+ input pin; as a result, the common-mode
voltage is limited to a range of +1.8V to 5.5V. The INA216 is a unidirectional current shunt
monitor, so the voltage drop created across the shunt resistor should be positive with respect
to the VIN– input pin in order for the device to operate correctly.
2.1
Measurement With Shunt
This connection method allows the user to install a shunt resistor on the evaluation board and connect the
common-mode voltage and load to incorporate the test device directly into a sample application, as
illustrates. To configure a measurement evaluation with a shunt, follow these procedures.
1. Install shunt resistor into the R2 location. If not using a surface-mount or through-hole shunt, refer to
for a summary of the R1 component specifications.
2. Connect the common-mode voltage to the V
IN+
terminal of T1.
3. Connect load to the V
IN–
terminal of T1.
Figure 2. Measurement with Shunt
4
INA216EVM
SBOU086–August 2011
Copyright © 2011, Texas Instruments Incorporated