Texas Instruments IC MCU 16B MSP430F2232TDA TSSOP-38 TID MSP430F2232TDA 데이터 시트

제품 코드
MSP430F2232TDA
다운로드
페이지 95
MSP430F22x2
MSP430F22x4
SLAS504G – JULY 2006 – REVISED AUGUST 2012
10-Bit ADC, Built-In Voltage Reference
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
I
VREF+
1 mA, REF2_5V = 0
2.2
Positive built-in
V
CC,REF+
reference analog
I
VREF+
0.5 mA, REF2_5V = 1
2.8
V
supply voltage range
I
VREF+
1 mA, REF2_5V = 1
2.9
I
VREF+
I
VREF+
max, REF2_5V = 0
2.2 V, 3 V
1.41
1.5
1.59
Positive built-in
V
REF+
V
reference voltage
I
VREF+
I
VREF+
max, REF2_5V = 1
3 V
2.35
2.5
2.65
2.2 V
±0.5
Maximum V
REF+
I
LD,VREF+
mA
load current
3 V
±1
I
VREF+
= 500 µA ± 100 µA,
Analog input voltage V
Ax
0.75 V,
2.2 V, 3 V
±2
REF2_5V = 0
V
REF+
load
LSB
regulation
I
VREF+
= 500 µA ± 100 µA,
Analog input voltage V
Ax
1.25 V,
3 V
±2
REF2_5V = 1
I
VREF+
= 100 µA to 900 µA,
ADC10SR = 0
400
V
REF+
load
V
Ax
0.5 x V
REF+
,
regulation response
3 V
ns
Error of conversion result
ADC10SR = 1
2000
time
1 LSB
Maximum
I
VREF+
±1 mA,
C
VREF+
capacitance at pin
2.2 V, 3 V
100
pF
REFON = 1, REFOUT = 1
V
REF+
(1)
Temperature
I
VREF+
= constant with
T
CREF+
2.2 V, 3 V
±100
ppm/°C
coefficient
(2)
0 mA
I
VREF+
1 mA
Settling time of
I
VREF+
= 0.5 mA, REF2_5V = 0,
t
REFON
internal reference
3.6 V
30
µs
REFON = 0 to 1
voltage
(3)
I
VREF+
= 0.5 mA,
ADC10SR = 0
1
REF2_5V = 0,
2.2 V
REFON = 1,
ADC10SR = 1
2.5
REFBURST = 1
Settling time of
t
REFBURST
µs
reference buffer
(3)
I
VREF+
= 0.5 mA,
ADC10SR = 0
2
REF2_5V = 1,
3 V
REFON = 1,
ADC10SR = 1
4.5
REFBURST = 1
(1)
The capacitance applied to the internal buffer operational amplifier, if switched to terminal P2.4/TA 2/A4/V
REF+
/ V
eREF+
(REFOUT = 1),
must be limited; the reference buffer may become unstable otherwise.
(2)
Calculated using the box method:
I temperature: (MAX(-40 to 85°C) – MIN(-40 to 85°C)) / MIN(-40 to 85°C) / (85°C – (–40°C))
T temperature: (MAX(-40 to 105°C) – MIN(-40 to 105°C)) / MIN(-40 to 105°C) / (105°C – (–40°C))
(3)
The condition is that the error in a conversion started after t
REFON
or t
RefBuf
is less than ±0.5 LSB.
Copyright © 2006–2012, Texas Instruments Incorporated
49