Calibration Screen
If the data flash screen is blank, then the bq30z554 in use may not be supported by the EVSW version in
use. An upgrade may be required.
9
Calibration Screen
9.1
How to Calibrate
The bq30z554 must be calibrated using power supplies, or a power supply and cell simulation resistors
(300
Ω
or less) before cells are attached. Before the bq30z554 is calibrated, do the following:
Connect and measure a 2-A current source from 1N (–) and Pack (–) to calibrate without using the
FETs (calibration using the FETs is not recommended).
Measure each cell voltage.
Measure the temperature of the pack.
Whether the foregoing steps are necessary depends on the type of calibration being performed.
9.2
Calibrate the bq30z554
To calibrate the bq30z554, do the following:
Select the types of calibration to be performed.
Enter the measured values for the types selected (except for CC Offset Calibration).
If Temperature Calibration is selected, select the sensor that is to be calibrated.
Click the appropriate button to initiate the desired calibration.
9.3
Board Offset Calibration
This performs the offset calibration for the current offset of the board.
Remove any current source, load, or external voltage from the PACK terminals.
Click the Calibrate Board Offset button.
9.4
Pack Voltage Calibration
This calibrates the voltage at the AFE Pack pin.
Ensure that Voltage Calibration has been performed for the pack. If Voltage Calibration is not
performed, then Pack Calibration calibrates incorrectly.
Remove load and external voltage applied between Pack+ and Pack–.
Click the Calibration Pack Voltage button to calibrate.
15
SLUUA36 – November 2012
bq30z554EVM SBS 1.1 Impedance Track™ Enabled Battery Management
Solution EVM