Configuration
Table 8. Overvoltage Protection selection
Jumper set to
Selection
No jumper
OVP enabled
Jumper shorted
OVP disabled
6.1.7
Onboard Dynamic Load Selection (SW501 for CPU and SW502 for GPU)
The onboard dynamic load can be set by SW501 and SW502.
Default setting: Push SW501 and SW502 to the right to disable the onboard dynamic load.
Table 9. Onboard Dynamic Load Selection
Switch set to
Dynamic Load Selection
Push SW501 to left (On position)
Enable 5-A onboard dynamic load at CPU
Push SW501 to right (Off position)
Disable 5-A onboard dynamic load at CPU
Push SW502 to left (On position)
Enable 5-A onboard dynamic load at GPU
Push SW502 to right (Off position)
Disable 5-A onboard dynamic load at GPU
6.1.8
Enable Selection (S101 for CPU and S201 for GPU)
The Vcore of CPU and GPU can be enabled and disabled by S101 and S201.
Default setting: Push S101 and S201 to the TOP(Off position) to disable both CPU and GPU
Table 10. Enable Selection
Switch set to
Dynamic Load Selection
Push S101 to bottom (On position)
Enable CPU Vcore
Push S101 to top (Off position)
Disable CPU Vcore
Push S201 to bottom (On position)
Enable GPU Vcore
Push S201 to top (Off position)
Disable GPU Vcore
6.2
5-V/3.3-V System Configuration
6.2.1
3.3VBIAS Enable Selection (J303)
3.3VBIAS Enable can be set by J303, EN_3.3VBIAS
Default setting: No Jumper shorts on J303 to enable the 3.3VBIAS
Note: 3.3VBIAS needs to always be enabled for CPU and GPU circuit
6.2.2
5-V/3.3-V Enable Selection (J301 for 5 V and J302 for 3.3 V)
5-V/3.3-V Enable can be set by J301 and J302, EN_5V and EN_3.3V
Default setting: Jumper shorts on J301 and J302 to disable 5 V/3.3 V.
Table 11. 5-V/3.3-V Enable Selection
Jumper set to
Selection
Jumper on J301
5-V Disabled
No jumper on J301
5-V Enabled
Jumper on J302
3.3-V Disabled
No jumper on J302
3.3-V Enabled
6.3
DDR 1.8-V/1.05-V CPU VTT Configuration
6.3.1
1.8-V/1.05-V Enable can be set by J402 for 1.8 V and J401 for 1.05 V, EN_1.8V and EN_1.05V
Default setting: Jumper shorts on J402 to disable 1.8 V. No Jumper on J401 to enable 1.05 V