TP8
TP4
Metal Ground Barrel
Probe Tip
Connector and Test Point Descriptions
www.ti.com
Figure 2. Tip and Barrel Measurement for Output Voltage Ripple
4.3.3
Channel 2 Output Voltage Monitoring (TP6 and TP7)
TPS53128EVM-620 provides two test points for measuring the voltage generated at the V
OUT2
output by
the module. This allows the user to measure the actual output voltage without losses from output cables
and connectors. Measure all dc output voltage between TP7 and TP6. To use TP7 and TP6, connect a
voltmeter positive terminal to TP7 and negative terminal to TP6.
For output ripple measurements, TP7 and TP6 allow a user to limit the ground loop area by using the tip
and barrel measurement technique shown in
4.3.4
Soft-Start Voltage Monitoring (TP1, TP2 and TP3)
TPS53128EVM-620 provides two test points for measuring the soft-start ramp voltages. TP1 monitors the
soft-start ramp of Channel 1. TP2 monitors the soft-start ramp of Channel 2. To use TP1 or TP2, connect
an oscilloscope probe between TP1 or TP2 and TP3.
4.3.5
Switching Node Monitoring (TP3, TP5 and TP11)
TPS53128EVM-620 provides two test points for measuring the switching node waveform voltages. TP5
monitors the switching node of Channel 1. TP2 monitors the switching node of Channel 2. To use TP5 or
TP11, connect an oscilloscope probe between TP5 or TP11 and TP3.
4.3.6
5-V Regulator Output Monitoring (TP3 and TP10)
TPS53128EVM-620 provides a test point for measuring the output of the internal 5-V regulator. TP10
monitors the output voltage of the internal 5-V regulator. To use TP10, connect a voltmeter positive
terminal to TP10 and negative terminal to TP3.